To configure the Sigur ACS access points, do the following:
- Go to
...
- the settings panel of the
...
- Sigur access point object
...
- , which is created on the
...
- basis of the
...
- Sigur server object in the Hardware tab of the System settings dialog box.
The Access point object is registered automatically when reading Sphinx ACS configuration.
The following parameters are automatically specified when reading Sphinx ACS configuration:
- Access point ID in the Sphinx ACS database (1);
- access point configuration (2);
In the ID field (1), enter the access point number on the Sigur server.
Info title Note. The Configuration field (2) displays the access point configuration, which is set
Access point configuration is setusing the switch on the card of
corresponding Sphinxthe corresponding Sigur ACS controller
(see reference documentation about Sphinx ACS).
- access control mode From the Type of access point drop-down list (3).
Sphinx ACS access points are configured as follows:
- , select the type of access point managed by the controller:
- Barrier;
- Door;
- Gate;
- NFC terminal;
- Turnstile.
- From the Entrance drop-down list (4), In the Entry dropdown list select the Region object corresponding to the area on the side of exit from the access point (4).
- In From the Exit dropdown list drop-down list (5), select the Region object corresponding to the area on the side of entrance to the access point (5).
- Set parameters of the access control parameters at entrance and exit (6):
From the Entrance and Exit drop-down lists, select the decision-making side for granting access:
- Intellect decides - access decision is automatically made by ACFA-Intellect.
Operator decides - access decision is made by the operator.
Info title Note. To process the request operator is to create a Photo ID interface object and configure it for the Operator’s query (Access granted) event. For more information about this object and its functions, please refer to Photo ID User Guide.
- If it is considered that passing is performed just after placing Set the Don’t wait access cycle for entry and Don’t wait access cycle for exit checkboxes if it is necessary to record the passage immediately after placing the access card to the reader, then check the Don’t wait access cycle for exit checkbox. If the passing passage is considered to be performed only after passing the access point (i.e. door sensor is triggered), uncheck unset this checkbox.
- .
- Click the Apply button to save all changes (87).
- Repeat steps 1-9 for all required Sphinx ACS access points.
Sphinx ACS access points are Sigur ACS access points are now configured.