- From the Type of controller: drop drop-down list select the type of AAN controller (AAN-32 or AAN-100) depending on the type of hardware being used (1).
- In the Time of confirmation by operator: field field enter the time period in seconds for operator to make a decision to grant or deny access (2).
- In the Time of escort card presentation: field field enter the time period in seconds between the presentation of the first and second access cards which, if exceeded, will result in access not being granted (3).
- From the PIN drop-down list select the length of PIN-code being used. Select the Do not use value if it's not required to use PIN-code (4).
Set the corresponding checkboxes if it's required to use additional 6 (5) or 32 (6) access levels.
Note title Attention! Maximum The maximum number of users storing that can be stored in controller memory decreases while using if the additional access levels are used.
- To configure antipassback set Set the Use APBaccess with escort checkbox (7) . To configure global antipassback regardless of number of AAN controllers, do the following:
- Create regions in the Intellect software package.
- Assign regions to readers. Match number of region in the AAN controller to each region in the Intellect softwareif it is necessary to confirm the access to the zone with the escort card.
In the Maximum number of cards: field field enter the maximum number of access cards that will be stored in the controller's memory (98).
Info title Note. The maximum number of access cards that can be stored in the controller's memory depends on the number of memory cards installed on it.
- Configure the antipassback:
If it is necessary to activate the zone antipassback control, set the Use checkbox (9) in the Zonal APB group (for details, see Configuring antipassback).
If necessary, from the Reset TZ drop-down list (10), select the time zone over which the double-pass control flags will be reset for all users.
If it is necessary to activate the temporary antipassback control, set the Use checkbox (11) in the Timed APB group (for details, see Configuring antipassback).
From the Store on drop-down list (12), select the location for storing the double-access control flags: Reader or APB zone.
Info title Note It is possible to activate only either zone or temporary antipassback control. Simultaneous operation of these antipassback control modes is not allowed.
- Click the Request time button (13) to request the AAN controller time.
- Click the Synchronize time button (14) to synchronize the AAN controller time with the computer time.
- Click the Apply button (15).