The Telemetry control panel object is used to register and configure the Universal PTZ control panel interface object in Axxon PSIM . The Universal PTZ control panel interface object that isused to control the PTZ devices.

The settings panel of the Telemetry control panel object is shown in the figure.

 Image Modified

Table The table describes the setting parameters corresponding to the elements of the settings panel of the Telemetry control panel object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Telemetry control panel object in the system

Sequence of numbers

-

From 1 and higher.

Digits, letters, periods, hyphen, dash, and underscore

NA

A line containing numbers, letters, periods, hyphen, dash, and underscore

Depends on the number of

the

the Telemetry control panel objects in the system

2

The Name*
field

Enter the value

into

in the field

Sets the name of the Telemetry control panel object in the system

Latin alphabet, Cyrillic, digits and service characters

Telemetry control panel

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Sets the state of the

Disables the Telemetry control panel object in the

digital

video surveillance system with distributed architecture

Boolean type

Clear

Setthe Telemetry control panel object is disabled and isn't used

Clearthe Telemetry control panel object is enabled and used

4

The Display
drop-down list

Select the value from the list

Sets the Display parent object in the

digital

system with distributed architecture to which the given Telemetry control panel object belongs

Names of the Display objects registered in the system

Name of the Display parent object

.

Depends on the number of the Display objects in the system

The Output window group

5

The Monitor
drop-down list

Select the value from the list

Sets the number of the monitor for which the coordinates are set

Number of the monitor in OS

1

From 1

-

to 16

6

The X field

Enter the value

into

in the field

Sets the X coordinate in the horizontal axis for the upper left corner of the

Telemetry

telemetry control panel

on

 window on the screen

% of the screen width

 30

From 0 to M*100, where M is the number of the installed monitors

7The W fieldEnter the value
into
in the fieldSets the width of the
Telemetry control panel interface window
telemetry control panel window% of the screen width
-
NAFrom 18 to M*100, where M is the number of the installed monitors

8

The Y field

Enter the value

into

in the field

Sets the Y coordinate in the vertical axis for the upper left corner of the

Telemetry

telemetry control panel window on the screen

% of the screen height

30

From 0 to M*100, where M is the number of the installed monitors

9

The H field

Enter the value

into

in the field

Sets the height of the

Telemetry

telemetry control panel

interface

 window

% of the screen height

-

NA

From 34 to M*100, where M is the number of the installed monitors

10

The Current coordinates* Image Added button

Click the button

Sets the current coordinates of the Telemetry control panel object in the X, Y, W, and H fields

-
NA
-
NA
-
NA

11

The Allow window moving
checkbox

Set the checkbox

Allows moving the

Telemetry

 telemetry control panel using the mouse

Boolean type

Set

Setallow moving the

Telemetry

telemetry control panel window

Clear—disable moving the

Telemetry

telemetry control panel window

12

The Half-transparent window
checkbox

Set the checkbox

Displays

Sets the display of the telemetry control panel in the half-transparent

Telemetry control panel

way

Boolean type

Set

Setdisplay the half-transparent

Telemetry

telemetry control panel window

Clear

do not

don't display the half-transparent

Telemetry

telemetry control panel window

Out of the group

13

The Priority
drop-down list

Select the value from the list

Sets the priority of the PTZ devices' control

Names of the priorities to control the PTZ devices

Low priority

Low 

  • Forbidden—control of the PTZ device using the
Telemetry
  •  telemetry control panel is forbidden;
  • Low prioritycontrol of
the PTZ
  • the PTZ device using the
Telemetry
  •  telemetry control panel is performed after it controls the devices with
Normal
  • normal or
High
  • high priority;
  • Normal prioritycontrol of the PTZ device using the
Telemetry
  •  telemetry control panel is performed after it controls devices with
High
  • high priority;
  • High prioritycontrol of the PTZ device using the
Telemetry
  •  telemetry control panel is performed in the first
place
  • order

14

The Allow presets
checkbox

Set the checkbox

Allows saving the position of the PTZ device in the presets

Boolean type

Set

Set—allow saving the position of the PTZ device in the presets

Clear—disable saving the position of the PTZ device in the presets

15

The Allow hotkeys
checkbox

Set the checkbox

Enables the PTZ device control using the keyboard

Boolean type

Clear

Setkeyboard can be used to control the PTZ device

Clearkeyboard hotkeys cannot be used to control the PTZ device

16

The Available cameras with telemetry control
field

Automatically

Displays

Specifies the

video

cameras with the PTZ devices

Names of the Camera objects registered in the system

List of all Camera objects registered in the system

Depends on the number of the PTZ devices in the

digital

system with distributed architecture

17

The Selected cameras field

Select by clicking the arrow keys

Sets the

video

cameras with the PTZ devices that can be controlled using the

Telemetry

telemetry control panel

-

Names of the Camera objects registered in the system

NA

-

Depends on the number of the PTZ devices in the

digital

system with distributed architecture

18

The One to the right* Image Added button

Click the button

Moves the selected PTZ device from the Available cameras with telemetry control list to the Selected cameras list

-
NA
-
NA
-
NA

19

The One to the left* Image Added button

Click the button

Moves the selected PTZ device from the Selected cameras list to the Available cameras with telemetry control list

-
NA
-
NA
-
NA

20

The All to the right*Image Added button

Click the button

Moves all PTZ devices from the Available cameras with telemetry control list to the Selected cameras list

-
NA
-
NA
-
NA

21

The All to the left* Image Added button

Click the button

Moves all PTZ devices from the Selected cameras list to the Available cameras with telemetry control list

-
NA
-
NA
-
NA

*Name of the element isn't displayed in the settings panel of the given object.