Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Manufacturer

AAM Systems

Office address: Kraznokazarmennaya str., 13-402
Moscow
Post address: Kraznokazarmennaya str., 14
Moscow, 111250
Tel: +7 (495) 924-2227
Fax: +7 (495) 362-7262
E-mail: aam@aamsystems.ru
www.aamsystems.ru 


Integration type

SDK

Equipment

Hardware connection

RS-232, IP

Supported equipmenthardware

Equipment

Hardware

Function

Features

AAN-100

Network controller

Central processor - MC68311 CPU 32 bit
Memory - to 8 MB
Real time clock - yes
PC connection interfaces: RS232 - 1 or Ethernet - 1

Interfaces for connection with interface modules, security and relay panels: RS485 - 4 or Ethernet - 4 
AAN-32SNetwork controller
Central processor - MC68311 CPU 32 bit
Memory - to 2 MB
Real time clock - yes
PC connection interfaces: RS232 - 1
Interfaces for connection with interface modules, security and relay panels: RS485 - 1 or Ethernet - 1 
AAN-32NNetwork controller
Central processor - MC68311 CPU 32 bit
Memory - to 2 MB
Real time clock - yes
PC connection interfaces: Ethernet - 1
Interfaces for connection with interface modules, security and relay panels: RS485 - 1 or Ethernet - 1
AIM-2SLAccess controller

Central processor - M68HC11 CPU
Memory:
Work storage RAM: 128 KB
EEPROM: 512 kb

Real time clock - yes
Connection interfaces: Wiegand readers - 2
Interfaces for connection with interface modules, security and relay panels: RS485 - 1 or Ethernet - 1 
AIM-4SLAccess controller
Central processor - M68HC11 CPU
Memory:
Work storage RAM: 128 kB
EEPROM: 512 kb
Real time clock - yes
Connection interfaces: Wiegand readers - 4
Interfaces for connection with interface modules, security and relay panels: RS485 - 1 or Ethernet - 1 
AIO-168Security panel
Security loops – 16 
Relay outputs - 8 
Interfaces of connection to central controller: RS485 – 1 or Ethernet – 1
ASA-72Status panel
72 three-color LEDs
Display of alarms, malfunctions, duress, no alarms
Local confirmation of incoming signals
Local reset/check of LEDs
Sound alert for alarms or malfunctions
Support for 72 zones (security panel inputs, reader inputs, etc.)
Interface for connecting to the RS-485 controller
LED to indicate the connection to the controller
4 LEDs to indicate the connection to the controller for each AIO-8/16/168 alarm panel
Tamper sensor
Power failure sensor
Two general purpose alarm inputs

Protection

Licensing

There are four positions in the price-list for one module:

Integration with Apollo (one server)

Integration with Apollo (one reader)

Integration with Apollo AIO-168

Integration with Apollo (one ASA-72)

Integration with Apollo (one server) is an electronic guardant key protected Apollo SDK v.2 from protecting ApolloSDK from the manufacturer site and storing serial keys of all devices. There is at least one key for system.

If hardware is connected to several servers with Axxon PSIM core coreб then additional purchase of electronic protect keys is required for each second and next servers (Integration with Apollo (one reader)). Own configuration for each electronic key – in key—in accordance with settings in the object objects tree of the Axxon PSIM software

It is required to present all serial numbers of hardware at the time of module order.

Protection Licensing doesn't depend on number of connected senior panels (AAN-100 and\/or AAN-32). Protection Licensing depends only from number of connected terminals (readers, sensor/relay, ASA-72). It requires is connected with the specifics of module sublicensing in company-manufacturer of module.

Apollo SDK v.2 ApolloSDK software module works with AIM-*SL controllers directly. Also there is possibility to work with several AIM-*SL controllers using network controller converter ENI-110.