Hardware requirements for neural analytics operationObjects

image Image requirements for Neurocounter the Neural counter operation

For Requirements for the correct operation of Neurocounter, the following requirements must be met:

Note
titleAttention!

The correct operation of Neurocounter isn't guaranteed when using a fisheye lens.

the Neural counter are given in the table:

Camera
Video stream
  • Resolution must be at least 640x360 pixels. We also don't recommend using a resolution higher than 1920×1080, since higher resolution doesn't increase the detection quality, but significantly increases the consumption of resources. The optimal resolution for solving typical tasks is 1280x720 (see Configuring
Neurocounter
  • the Neural counter)
  • The frame rate per second in the video stream from the camera is at least 8 for solving typical tasks
  • Both colorless (gray) and color images
Note
titleAttention!
  • Correct operation of the detection tool isn't guaranteed if you use frames that were masked before they got into Axxon One by an IP camera or similar methods.
  • The correct operation of the Neural counter isn't guaranteed if you use a fisheye lens.
Lighting
  • Lighting in the scene is at least 50 lux. In conditions of insufficient or excessive lighting (night or light-striking), stable operation of the analytics isn't guaranteed
  • No abrupt changes in lighting
Scene and camera angle
  • Moving objects are visually separable from each other
  • The background is mostly static and doesn't change abruptly
  • Moving objects are minimally obscured by static objects in the scene (columns, trees, and so on)
  • The analyzed scene doesn't have reflective surfaces and sharp shadows from moving objects. If present, they must be masked
  • Camera shake doesn't result in image offsets greater than 1% of the frame size