Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Section
Column
width50%
Panel
borderColor#CCCCCC
bgColor#FFFFFF
titleBGColor#F0F0F0
borderStylesolid
titleOn the page:

Table of Contents


Column


Configuring the parameters

...

To configure the Close-standing people

...

detector, do the following:

  1. Create

...

  1. the Human pose detector (see Configuring the Human pose detector).
  2. Below the

...

  1. Human pose detector, click Create… Close-standing people

...

  1. detector.

By default, the Close-standing people detection triggers detector generates an event when "skeleton" bounding boxes around people collide. 

Info
titleNote

Bounding boxes are not displayed in the interface. They are usually a bit larger than the "skeletons" dimensions.

If necessary, you can change the detection tool detector parameters. The list of parameters is given in the table:

ParameterValueDescription
Other
EnableYesThe
detection tool
detector is enabled by default. To disable the
detection tool
detector, select
the 
the No
 value
 value
No
NameClose-standing people
detection
detectorEnter the
detection tool
detector name or leave the default name
TypeClose-standing people
detection
detectorName of the
detection tool
detector type (non-editable field)
Basic settings
Distance sensitivity2Specify the distance between people in meters at which the
detection tool must trigger. Alarm will be
detector must generate an event. An event is generated if the distance between people in the frame is equal to or less than the specified distance. The value must be in the range [0, 20]
Leveling rod length1.7Specify the average height of a person in meters, according to which the leveling rods are set. The value must be in the range [0, 3]
Number of measurements in a row to trigger detection4Specify the minimum number of frames with close-standing people for the
detection tool to trigger. 
detector to generate an event. The value must be in the range [1, 100].
Increasing the value can help eliminate false
alarms,
events but increases the risk of skips. 
Decreasing the value can help reduce skips,
but increases
but increases the probability of false
alarms
events

To save the parameters of the detection tooldetector, click the Apply Apply Image Modified button. To cancel the changes, click the Cancel Image Removed button. Cancel Image Added button.

Configuring the detection area

To configure the detection area, do the following:

  1. Click in the preview window.
  2. Select Detection area.
    Image Added
  3. Set the detection area using the anchor points Image Added.
    Info
    titleNote
    • For convenience of configuration, you can "freeze" the frame. Click the Image Added button. To cancel the action, click this button again.
    • To hide the detection area, click the Image Added button. To cancel the action, click this button again.
    • To remove the detection area, click the Image Added button.

  4. Click the Apply Image Added button.

Configuration of the detection area is complete. 

Configuring the frame perspective 

if If you want to change the triggering distance that must generate an event, you must configure the frame perspective:

Note
titleAttention!

For portrait-oriented scenes (such as corridor, shopping aisle, warehouse aisle, and so on), we recommend configuring the perspective in any case.

  1. In the preview window, click the
  2.  Image Removed button.
  3. Image Added button.
  4. Click in the preview window. 
  5. Select Leveling rod.
    Image Added
  6. Specify the size of the same object in different parts of the frame by eye
  7. .
  8. :
    • To create a leveling rod, left-click the video image to add two anchor points.
  9. You must set
    • Set at least

  10. three leveling rods. Image Removed
    • three calibration rods. The lower anchor points of any three rods must not be located on the same line (horizontal, vertical, slanting, and so on).

    • The size of the leveling rod must be about the average height of a person at this part of the frame.
    • You can resize the rod by stretching its anchor points
  11.  
    • Image Added. You can move it on screen
  12. by 
  13. Image Removed
    • Image Added
      Note
      titleAttention!

      When you set up leveling rods, the following conditions must be met:

      1. the rods that are located at the same distance from the camera lens
  14. ,
      1. must be of the same size;
      2. the feet of the rods must be located on the same surface (for example, floor);
      3. in complex scenes, we recommend adding more than three rods to increase the accuracy of the detection;

      4. in the parts of the frame where the lens vertical distortion is observed, the rods must be parallel to the nearest vertical objects (for example, door

  15. ,
      1. or wardrobe);

      2. for portrait-oriented scenes (such as corridor, shopping aisle, warehouse aisle, and so on), the arrangement of the rods must form triangles.
      Info
      titleNote
      • For convenience of configuration, you can "freeze" the frame. Click the
  16.  Image Removed button
      • Image Added button. To cancel the action, click this button again.
      • The area for detection is displayed by default. To hide it, click the
  17.  Image Removed 
      • Image Added button. To cancel the action, click this button again.
      • To delete a rod, click the
  18.  Image Removed button
      • Image Added button.

  19. Click
  20. the Apply button
  21. the Apply Image Added button.