The Web-server object is used for video surveillance via a web browser and the TCP/IP communication environment. The settings panel of the Web-server object and its description are shown in the figures and tables given below.
The Basic settings tab:
№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* | Automatically | Displays the identification number of the Web |
server object in the |
video surveillance system with |
distributed architecture | Sequence of numbers |
NA | From 1 |
to 2147483647. Depends on the number of the Web |
server objects in the |
video surveillance system with |
distributed architecture | ||
2 | The Name* | Enter the value |
in the field | Sets the name of the Web |
server object in the |
video surveillance system with |
distributed architecture | Latin alphabet, Cyrillic, digits and service characters | Web-server | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | The Disable | Set the checkbox |
Disables the Web server object in the |
video surveillance system with |
distributed architecture | Boolean type | Clear | Set—the Web |
server object is disabled and isn't used Clear—the Web |
server object is enabled and used | |||
4 | The Computer | Select the value from the list | Sets the Computer parent object of the |
system with |
distributed architecture |
to which the given Web |
server object belongs |
Names of the Computer objects registered in the system | Name of the Computer parent object | Depends on the number of the Computer objects in the |
video surveillance system with |
distributed architecture | ||||||
The HTTP-server group | ||||||
5 | The Port number | Enter the value |
in the field | Sets the number of the port used by the HTTP |
server (used for video surveillance via a web browser, including via the internet) | Sequence of numbers | 80 | Any valid unused port numbers. The number of ports is determined by the system administrator |
The Number of connections | Enter the value |
in the field | Sets the maximum possible number of connections to the |
server via the Web |
server module. Each request to view the video signal from each camera and each request to control all PTZ devices |
, regardless of their number, is considered as a connection |
Positive integers | 100 | Any integer. If you specify the 0 value |
in the |
video surveillance monitor of the Web-server module, video signals |
aren't |
displayed | |
The Parallel exports | Enter the value |
in the field |
Determines the maximum allowed number of archive files to be uploaded simultaneously | Sequence of numbers | 2 | From 1 and above. If you leave the field blank, the lowest possible value is used | |||
The HTTPS-server group | ||||||
6 | The Use HTTPS protocol | Set the checkbox | Enables the HTTPS protocol when |
you transmit data via the Web-server | Boolean type | Clear |
Set—the HTTPS protocol is used |
Clear—the HTTPS protocol isn't used | |
The Key | Enter the value |
in the field |
Sets the path to the folder of the key for data transmission via the HTTPS protocol | Latin alphabet, Cyrillic, digits and service characters | C:\Program Files (x86)\Axxon PSIM\Modules\SSL\ssl_internal.key | Depends on the location of data encryption key when |
you transmit data via the HTTPS protocol | |
The Certificate | Enter the value |
in the field |
Sets the path to the folder of the certificate for data transmission via the HTTPS protocol | Latin alphabet, Cyrillic, and service characters | C:\Program Files (x86)\Axxon PSIM\Modules\SSL\ssl_internal.cert | Depends on the location of certificate file when |
you transmit data via the HTTPS protocol | |
The Port number | Enter the value |
in the field | Sets the number of the port used for the HTTPS |
server (used for video surveillance in a web browser and |
via the internet) | Sequence of numbers | 443 | Any available unused port numbers. The number of ports is |
determined by the system administrator |
Out of the group | ||||||
7 | The Default user | Select the value from the list | Sets the user with |
permissions and authority to conduct the video surveillance from the Remote workstation using the Web |
server module | Names of the users registered in the system and added to the |
permissions |
NA | Depends on the number of |
users registered in Axxon PSIM | |||
8 | The ECHD translation | Set the checkbox | Enables |
the use of the |
HTTP requests used for integration with ECHD | Boolean type | Clear | Set—requests used for integration with ECHD are |
executed for the Camera objects on the basis of which the ECHD channel objects are created Clear—requests used for integration with ECHD |
aren't executed | |||||
9 | The Use NAT address checkbox | Set the checkbox | Enables the router address substitution in the ECHD requests | Boolean type | Clear |
Set—when you request the URL |
streams via the HTTP API, the IP address of the router specified in the settings panel of the RTSP |
Server object is substituted in the response to the request Clear—when |
you request the URL |
streams via the HTTP API, the IP address of the |
server in its local network is returned in response to the request |
The List of cameras tab:
№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range |
10 | The Range | Click the button | Opens the window for bulk |
addition of cameras (see Bulk selecting and configuring cameras for the Web-server) |
NA |
NA |
NA | |||
11 | The Clear | Click the button | Clears the list of the added cameras |
NA |
NA |
NA | |||
12 | The Add all | Click the button | Adds to the list of cameras all Camera objects created in the system |
NA |
NA |
NA | |||
13 | The Number | Select the value from the list | Sets the number of the camera the video from which is transmitted to the remote workstation |
via the Web |
server module | Identifiers of the Camera objects registered in the system |
NA | Depends on the number of |
cameras in the |
video surveillance system with |
distributed architecture | ||
The Camera | Select the value from the list | Sets the name of the camera the video from which is transmitted to the remote workstation |
via the Web |
server module | Names of the Camera objects registered in the system |
NA | Depends on the number of |
cameras in the |
video surveillance system with |
distributed architecture | |||||
The Video stream | Select the value from the list | Sets the number of the video stream used for displaying in the Web-server interface | Numbers of video streams enabled on the camera and the By default value | By default | Depends on the number of the camera enabled streams |
The Live video | Select the value from the list | Sets the source of live video that is displayed in the Web-server interface | Available means to get live video |
server | Server—live video is received from the |
server to which the camera is connected. Videogate—live video is received |
through the videogate. Note. If a camera |
isn't configured to transmit video through the |
videogate, |
this item is unavailable in the list | |||
The Archive | Select the value from the list | Sets the source of the archive video that is displayed in the Web-server interface | Available means to get archive video |
server |
|
|
|
|
|
|
Backup archive—archive video is received from the Backup archive
The Microphone |
Select the value from the list | Sets the name of the microphone associated with the camera, the audio from which |
is transmitted through the Web-server | Names of the Microphone objects registered in the system |
NA | Depends on the number of the Microphone objects in the |
video surveillance system with |
distributed architecture | ||
The Speaker | Select the value from the list | Sets the name of the speaker associated with the camera, which |
is used to |
play back the audio received from the client | Names of the Speaker objects registered in the system |
NA | Depends on the number of the Speaker objects in the |
video surveillance system with |
distributed architecture | ||
The Compression | Select the value from the list | Sets the compression level of the video signal transmitted to the remote workstations using the Web |
server module. Increasing the level of compression leads to the deterioration of the video signal quality | Reference compression levels |
NA | Not defined, from 1 |
to 5. |
The 1 value corresponds to the minimum compression level, the 5—to the maximum compression level. If the compression level |
isn't specified, the video signal is transmitted with the same compression level as set for recording and transmitting |
videos to the network | ||
The Control | Select the value from the list | Sets the camera control (arm/disarm, PTZ, recording to the archive) according to the user |
permissions | Boolean type | Enabled | Enabled—camera control according to the user |
permissions is enabled Disabled—camera control is disabled regardless of the user |
permissions | ||
14 | The PTZ control drop-down list | Select the value from the list |
Sets the |
priority of the PTZ control during video surveillance using a web browser | Names of the PTZ control priorities | Low priority |
|
|
|
|
The RTSP settings tab:
№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range |
15 |
The RTSP server | Automatically | Displays the list of the RTSP Server objects registered in the system to process ECHD requests | Name of the RTSP Server objects | NA | List of the RTSP Server objects registered in the system to process ECHD requests |
The RTSP server | Set the checkbox | Sets the RTSP server (one or several) |
to process |
ECHD requests | Names of the RTSP |
Server objects registered in the system |
Not defined
Clear | Set—RTSP server is used to process ECHD requests |
Clear—RTSP server isn't |
used to process ECHD requests |
*Name of the element isn't displayed in the settings panel of the given object