Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The Web-server object is used for video surveillance via a web browser and the TCP/IP communication environment. The settings panel of the Web-server object and its description are shown in the figures and tables given below.

The Basic settings tab:

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Web

-

server object in the

digital

video surveillance system with

the

distributed architecture

Sequence of numbers

-

NA

From 1

and above

to 2147483647.

Depends on the number of the Web

-

server objects in the

digital

video surveillance system with

the

distributed architecture

2

The Name*
field

Enter the value

into

in the field

Sets the name of the Web

-

server object in the

digital

video surveillance system with

the

distributed architecture

Latin alphabet, Cyrillic, digits and service characters

Web-server

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Sets the state (enabled or disabled) of the Web-server

Disables the Web server object in the

digital

video surveillance system with

the

distributed architecture

Boolean type

Clear

Setthe Web

-

server object is disabled and isn't used

Clearthe Web

-

server object is enabled and used

4

The Computer
drop-down list

Select the value from the list

Sets the Computer parent object of the

digital

system with

the

distributed architecture

,

to which the given Web

-

server object belongs

Name

Names of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the

digital

video surveillance system with

the

distributed architecture

The HTTP-server group

5



The Port number
field

Enter the value

into the

in the field

Sets the number of the port used by the HTTP

-

server (used for video surveillance via a web browser, including via the internet)

Sequence of numbers

80

Any valid unused port numbers.

The number of ports is determined by the system administrator

.

The Number of connections
field

Enter the value

into

in the field

Sets the maximum possible number of connections to the

Server

server via the Web

-

server module.

Each request to view the video signal from each camera and each request to control all PTZ devices

regadless

, regardless of their number, is considered as a connection

Sequence of numbers
Positive integers

100

Any integer.

If you specify the 0 value

is specified

in the

Video

video surveillance monitor of the Web-server module, video signals

won

aren't

be

displayed

The Parallel exports
field

Enter the value

into

in the field

Sets

Determines the maximum allowed number of archive files to be uploaded simultaneously

Sequence of numbers

2

From 1 and above.

If you leave the field blank, the lowest possible value is used

The HTTPS-server group

6




The Use HTTPS protocol
checkbox

Set the checkbox

Enables the HTTPS protocol when

transmitting

you transmit data via the Web-server

Boolean type

Clear

Set—

Setthe HTTPS protocol is used

Clear—

Clearthe HTTPS protocol isn't used

The Key
field

Enter the value

into

in the field

Key

Sets the path to the folder of the key for data transmission via the HTTPS protocol

Latin alphabet, Cyrillic, digits and service characters

C:\Program Files (x86)\Axxon PSIM\Modules\SSL\ssl_internal.key

Depends on the location of data encryption key when

transmitting

you transmit data via the HTTPS protocol

The Certificate
field

Enter the value

into the

in the field

Certificate

Sets the path to the folder of the certificate for data transmission via the HTTPS protocol

Latin alphabet, Cyrillic, and service characters

C:\Program Files (x86)\Axxon PSIM\Modules\SSL\ssl_internal.cert

Depends on the location of certificate file when

transmitting

you transmit data via the HTTPS protocol

The Port number
field

Enter the value

into

in the field

Sets the number of the port used for the HTTPS

-

server (used for video surveillance in a web browser and

in

via the internet)

Sequence of numbers

443

Any available unused port numbers.

The number of ports is

specified

determined by the system administrator

Not in a
Out of the group

7

The Default user
drop-down list

Select the value from the list

Sets the user with

rights

permissions and authority to conduct the video surveillance from the Remote workstation using the Web

-

server module

Names of the users registered in the system and added to the

rights

permissions

Not defined

NA

Depends on the number of

the

users registered in Axxon PSIM

8

The ECHD translation
checkbox

Set the checkbox

Enables

to

the use of the

http

HTTP requests used for integration with ECHD

Boolean type

Clear

Setrequests used for integration with ECHD are

run

executed for the Camera objects on the basis of which the ECHD channel objects are created

Clearrequests used for integration with ECHD

are not run

aren't executed

9The Use NAT address
checkbox
Set the checkboxEnables the router address substitution in the ECHD requestsBoolean typeClear
Set—when requesting
Set—when you request the URL
of
streams via the HTTP API, the IP address of the router specified in the settings panel of the RTSP
-
Server object is substituted in the response to the request

Clear—when
requesting
you request the URL
of
streams via the HTTP API, the IP address of the
Server
server in its local network is returned in response to the request

The List of cameras tab:

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

10

The Range
button

Click the button

Opens the window for bulk

selection

addition of cameras (see Bulk selecting and configuring cameras for the Web-server)

-
NA
-
NA
-
NA

11

The Clear
button

Click the button

Clears the list of the added cameras

-
NA
-
NA
-
NA

12

The Add all
button

Click the button

Adds to the list of cameras all Camera objects created in the system

-
NA
-
NA
-
NA

13

The Number
drop-down list

Select the value from the list

Sets the number of the camera the video from which is transmitted to the remote workstation

using

via the Web

-

server module

Identifiers of the Camera objects registered in the system

Not defined
NA

Depends on the number of

the

cameras in the

digital

video surveillance system with

the

distributed architecture

The Camera
drop-down list

Select the value from the list

Sets the name of the camera the video from which is transmitted to the remote workstation

using

via the Web

-

server module

Names of the Camera objects registered in the system

Not defined
NA

Depends on the number of

the

cameras in the

digital

video surveillance system with

the

distributed architecture

The Video stream
drop-down list

Select the value from the list

Sets the number of the video stream used for displaying in the Web-server interface

Numbers of video streams enabled on the camera and the By default value

By default

Depends on the number of the camera enabled streams

on the camera

The Live video
drop-down list

Select the value from the list

Sets the source of live video that is displayed in the Web-server interface

Available means to get live video

Server

server

Serverlive video is received from the

Server

 server to which the camera is connected.

Videogatelive video is received

from the Videogate

through the videogate.

Note. If a camera

is not

isn't configured to transmit video through the

Videogate

videogate,

then

this item is unavailable in the list

The Archive
drop-down list

Select the value from the list

Sets the source of the archive video that is displayed in the Web-server interface

Available means to get archive video

Server

server

  • Disabled—archive video isn't transmitted;
  • Serverarchive video is received from the
Server to
  •  server to which the camera is connected;
  • Backup archivearchive video is received from the backup archive;
  • Videogatearchive video is received from the
Videogate
  • videogate archive. If a camera
is not
  • isn't configured to transmit video through the
Videogate
  • videogate,
then Microphone
  • this item is unavailable in the list
.

Backup archivearchive video is received from the Backup archive 

The Microphone
drop-down list


Select the value from the list

Sets the name of the microphone associated with the camera, the audio from which

will be

is transmitted through the Web-server

Names of the Microphone objects registered in the system

Not defined
NA

Depends on the number of the Microphone objects in the

digital

video surveillance system with

the

distributed architecture

The Speaker
drop-down list

Select the value from the list

Sets the name of the speaker associated with the camera, which

will be

is used to

playback

play back the audio received from the client

Names of the Speaker objects registered in the system

Not defined
NA

Depends on the number of the Speaker objects in the

digital

video surveillance system with

the

distributed architecture

The Compression
drop-down list

Select the value from the list

Sets the compression level of the video signal transmitted to the remote workstations using the Web

-

server module. Increasing the level of compression leads to the deterioration of the video signal quality

Reference compression levels

Not defined
NA

Not defined, from 1

to 5.

Value 1

The 1 value corresponds to the minimum compression level, the 5to the maximum compression level.

If the compression level

is not

isn't specified, the video signal is transmitted with the same compression level as set for recording and transmitting

video

videos to the network

The Control
drop-down list

Select the value from the list

Sets the camera control (arm/disarm, PTZ, recording to the archive) according to the user

rights

permissions

Boolean type

Enabled

Enabledcamera control according to the user

rights

permissions is enabled

Disabledcamera control is disabled regardless of the user

rights

permissions

14The PTZ control
drop-down list
Select the value from the list
Set
Sets the
prioritiy
priority of the PTZ control during video surveillance using a web browserNames of the PTZ control prioritiesLow priority
  • Forbidden
option
  • —option of the PTZ control
in
  • with a web browser
is disabled
  • at video surveillance;
  • Low prioritylow priority of control;
  • Medium prioritymedium priority of control;
  • High priorityhigh priority of control

The RTSP settings tab:

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

15
RTSP-server

The RTSP server
list

Automatically

Displays the list of the RTSP Server objects registered in the system to process ECHD requests

Name of the RTSP Server objects

NA

List of the RTSP Server objects registered in the system to process ECHD requests

The RTSP server
checkbox

Set the checkbox

Sets the RTSP server (one or several)

to

 to process

the

ECHD requests

Names of the RTSP

-server

Server objects registered in the system

Not defined

Set—RTSP Server will be

Clear

Set—RTSP server is used to process ECHD requests

Clear—RTSP Server won

Clear—RTSP server isn't

be

used to process ECHD requests

*Name of the element isn't displayed in the settings panel of the given object