The table describes the setting parameters corresponding to the elements of the settings panel of the Telemetry control panel object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* | Automatically | Displays the identification number of the Telemetry control panel object in the system |
Digits, letters, periods, hyphen, dash, and underscore | NA | A line containing numbers, letters, periods, hyphen, dash, and underscore Depends on the number of the Telemetry control panel objects in the system | ||
2 | The Name* | Enter the value in the field | Sets the name of the Telemetry control panel object in the system | Latin alphabet, Cyrillic, |
digits, and service characters | Telemetry control panel | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 | ||||
3 | The Disable | Set the checkbox | Disables the Telemetry control panel object in the video surveillance system with distributed architecture | Boolean type | Clear | Set—the Telemetry control panel object is disabled and isn't used Clear—the Telemetry control panel object is enabled and used |
4 | The Display | Select the value from the list | Sets the Display parent object in the system with distributed architecture to which the given Telemetry control panel object belongs | Names of the Display objects registered in the system | Name of the Display parent object |
Depends on the number of the Display objects in the system | ||||||
The Output window group | ||||||
5 | The Monitor | Select the value from the list | Sets the number of the monitor for which the coordinates are set | Number of the monitor in OS | 1 | From 1 to 16 |
6 | The X field | Enter the value in the field | Sets the X coordinate in the horizontal axis for the upper left corner of the |
telemetry control panel |
window on the screen | % of the screen width | 30 | From 0 to M*100, where M is the number of the installed monitors |
7 | The W field | Enter the value in the field | Sets the width of the |
telemetry control panel |
window | % of the screen width | NA | From 18 to M*100, where M is the number of the installed monitors |
8 | The Y field | Enter the value in the field | Sets the Y coordinate in the vertical axis for the upper left corner of the |
telemetry control |
panelwindow on the screen | % of the screen height | 30 | From 0 to M*100, where M is the number of the installed monitors |
9 | The H field | Enter the value in the field | Sets the height of the |
telemetry control panel |
window | % of the screen height | NA | From 34 to M*100, where M is the number of the installed monitors |
10 | The Current coordinates* | Click the button | Sets the current coordinates of the Telemetry control panel |
object in the X, Y, W, and H fields | NA | NA | NA |
11 | The Allow window moving | Set the checkbox | Allows moving the |
telemetry control panel using the mouse | Boolean type | Set | Set—allow moving the |
telemetry control panelwindow Clear—disable moving the |
telemetry control panelwindow | |||
12 | The Half-transparent window | Set the checkbox | Sets the display of the |
telemetry control panel in the half-transparent way | Boolean type | Set | Set—display the half-transparent |
telemetry control panelwindow Clear—don't display the half-transparent |
telemetry control panel window | ||||||
Out of the group | ||||||
13 | The Priority | Select the value from the list | Sets the priority of the PTZ devices' control | Names of the priorities to control the PTZ devices | Low |
|
|
|
|
|
|
|
|
|
| ||||||
14 | The Allow presets | Set the checkbox | Allows saving the position of the PTZ device in the presets | Boolean type | Set | Set—allow saving the position of the PTZ device in the presets Clear—disable saving the position of the PTZ device in the presets |
15 | The Allow hotkeys | Set the checkbox | Enables the PTZ device control using the keyboard | Boolean type | Clear | Set—keyboard can be used to control the PTZ device Clear—keyboard hotkeys cannot be used to control the PTZ device |
16 | The Available cameras with telemetry control | Automatically |
Specifies the cameras with the PTZ devices | Names of the Camera objects registered in the system | List of all Camera objects registered in the system | Depends on the number of the PTZ devices in the system with distributed architecture |
17 | The Selected cameras field | Select by clicking the arrow keys | Sets the cameras with the PTZ devices that can be controlled using |
the telemetry control panel | Names of the Camera objects registered in the system | NA | Depends on the number of the PTZ devices in the system with distributed architecture | |||
18 | The One to the right* | Click the button | Moves the selected PTZ device from the Available cameras with telemetry control list to the Selected cameras list | NA | NA | NA |
19 | The One to the left* | Click the button | Moves the selected PTZ device from the Selected cameras list to the Available cameras with telemetry control list | NA | NA | NA |
20 | The All to the right* | Click the button | Moves all PTZ devices from the Available cameras with telemetry control list to the Selected cameras list | NA | NA | NA |
21 | The All to the left* | Click the button | Moves all PTZ devices from the Selected cameras list to the Available cameras with telemetry control list | NA | NA | NA |
*Name of the element isn't displayed in the settings panel of the given object.