The AxxonOne Manager You can use the AxxonOne manager hardware object is used to set up integration with Axxon One. Only You can create only one AxxonOne Manager can be created manager per Axxon PSIM server, so if you need integration with multiple Axxon One domains, you will need to must use multiple multiple Axxon PSIM servers.
Section |
---|
Column |
---|
| Panel |
---|
borderColor | #CCCCCC |
---|
bgColor | #FFFFFF |
---|
titleBGColor | #F0F0F0 |
---|
borderStyle | solid |
---|
title | On this page: |
---|
| |
|
|
Creating AxxonOne
...
manager
- Go to the Hardware tab in the system settings.
- Right-click on the the Computer object, and in the context menu that appearsopens, select Create object → AxxonOne Managermanager.
Image Removed Info |
---|
|
The Computer object should must correspond to the Axxon PSIM Server which server that is selected for integration. |
- The Number and Name fields will be are filled in automatically, but you can edit them if needed.
Image Removed - Click Apply.
- On the WEB-server Axxon One tab on the settings panel of the AxxonOne manager object, set the Enable checkbox.
As a result, three objects will be are created: AxxonOne Managermanager, along with ONVIF Server and RTSP Server associated with it.
The ONVIF Server (AxxonOne Managermanager) and RTSP Server (AxxonOne Managermanager) objects are used to set up integration using the Axxon One Web Server and are created by default. There is no need to delete or configure them; they should must remain as they are.
Configuring AxxonOne
...
manager
- Select the created AxxonOne Managermanager in the hardware tree.
- Go to the (1), go to the Integration with Axxon One tab (2), and set the Enable checkbox (3).
Image Removed - Enter the information of the Axxon One instance you are connecting to (4):
Field | Description | Default value |
---|
Address | IP - address | 127.0.0.1 |
Port | Port for communication with Client client (NativeBL port) | 20109 |
Base port | Port for operations within a domain | 20111 |
Web port | Web Server port (HTTP port for failover server) | 80 |
Login | Axxon One username | root |
Password | Axxon One password | root |
If you use a cloud connection is used for authorization in in Axxon One, set the Cloud checkbox.
- Click the Update button (5) to button to synchronize with Axxon One. This button initiates reading and updating the Axxon One configuration to retrieve information and send it to Axxon PSIM:
Image Removed
Note |
---|
|
Specifics of synchronization with Axxon One using the Update button: - After clicking you click the button, you must wait for the process to complete without taking any further actions. This ensures that the states of Axxon One objects are correctly transferred.
- If the configuration of a running Axxon One Server server was previously retrieved and during the next synchronization the server status is "off," the equipment hardware state in Axxon PSIM will remain remains unchanged. This is done to prevent accidental configuration clearing, for example, if the Axxon One server is rebooting during synchronization.
- If you enter data of a new Axxon One domain for synchronization, the data from of the previously synchronized domain will be deleted. If synchronization is done with a server from the same domain, the data will remain.
- The equipment hardware list, which was already retrieved, will be synchronized between Axxon PSIM and Axxon One "on the fly." However, to obtain information about new equipment hardware or changes in the Axxon One configuration, you should must click the Update button again.
- If you delete in Axxon PSIM devices and macros received from Axxon One (and they remain in Axxon One), they will be are recreated in Axxon PSIM during the next synchronization.
- Equipment Hardware objects retrieved from Axxon One are created in Axxon PSIM without configuration panels, as they can only be configured in Axxon One.
- Macros are created without predefined conditions, but they you can be configured configure them if needed. For more information, see Working with macros and events received from Axxon One.
|
The result of the synchronization will be is displayed in the information fields fields Last successful synchronization and Last synchronization state (6). If the synchronization was successful, the equipment hardware received from Axxon One will appear appears in the equipment hardware list, and the received macros will appear in the the Macros list on the Programming tab.
Image Removed
Image RemovedIn the Node name drop-down list, select the Axxon One
- If you connect to the Axxon One failover server, set the Failover server checkbox and select the server, the cameras from which will be displayed in the Axxon One Monitor interface (7), from the drop-down list on the right. If you connect to a regular server, not the Axxon One failover server, you can skip this step.
In the Path field, specify the path to the previously installed Axxon One Client client (see Pre-configuration of Axxon One) , which that will be used to launch the the Axxon One Monitor interface object (8). The default path is: C:\Program Files\AxxonSoft\AxxonOne\bin\AxxonOne.exe.
Note |
---|
|
Note that this path must be the same on all computers where you want to run the Axxon One Client client (AxxonOne.exe) is to be run. This means that the the Axxon One Client client must be pre-installed in the same folder on all computers. |
- Click Apply.
Integration with Axxon One is complete.
Deleting Axxon One configuration
To completely remove delete the integration with Axxon One configured as described above, do the following:
- Make sure that the last synchronization with Axxon One was successful (check the Last successful synchronization and Last synchronization state fields). If necessary, click Update to synchronize.
- On the AxxonOne Manager the settings panel of AxxonOne manager, click the Delete configuration button.
Image Removed
- A Delete configuration window will openopens. Click OK to confirm.
Image Removed
As a result, all equipment hardware and macro lists associated with this integration will be deleted. If an you configured an Axxon One Monitor interface object was configured, its camera list will also be cleared accordingly.