№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number | Automatically | Displays the identification number of the PS-RTP Server object in the system | Sequence of numbers | - | Depends on the number of the PS-RTP Server objects in the system |
2 | Name | Enter the value into the field | Sets the name of the PS-RTP Server object | Latin, Cyrillic and service characters | PS-RTP Server | A line containing a sequence of any characters (letters, digits, service characters except for the > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state (disabled or enabled) of the PS-RTP Server object | Boolean type | Clear | Set—the PS-RTP Server object is disabled and isn't used Clear—the PS-RTP Server object is enabled and used |
4 | Computer | Select the value from the list | Sets the Computer parent object of the digital system with the distributed architecture to which the given PS-RTP Server object belongs | Names of the Computer objects registered in the system | The name of the Computer parent object | Depends on the number of the Computer objects in the digital video surveillance system with the distributed architecture |
The Main tab | ||||||
5 | IP | Select the value from the list | Sets the IP address of the network interface using which the third-party software will control the devices registered in Intellect via the GB28181 protocol | IP address | Depends on the parameters of the network connection | Depends on the parameters and the number of the network connections |
6 | Port | Enter the value into the field | Number of the port through which the third-party software will be connected via the GB28181 protocol | Sequence of numbers | 5060 | 0–65535 |
7 | Transport | Select the value from the list | Transport protocol for the data transmission | Supported transport protocols | UDP | UDP, TCP |
8 | from | Enter the value into the field | Lower limit of the RTP port range | Sequence of numbers | - | 0–65535 |
9 | to | Enter the value into the field | Upper limit of the RTP port range | Sequence of numbers | - | 0–65535 |
10 | Server ID | Automatically | The identifier of the Intellect Server that is used by the third-party software to connect to the RS-RTP Server via the GB2818 GB28181 protocol | - | - | - |
The List of devices tab | ||||||
11 | Type | Select the value from the list | The type of object to be controlled via the GB2818 GB28181 protocol | Names of the types of objects in Intellect objects tree | - | Depends on the number of the objects created in Intellect objects tree |
12 | Name | Select the value from the list | The name of the object to be controlled via the GB2818 GB28181 protocol | Names of the objects in Intellect objects tree | - | Depends on the number of the objects created in Intellect objects tree |
13 | Device ID | Automatically | The identifier of the device that will be used in the third-party software to control objects via the GB28181 protocol | - | - | - |
The Connection to external server tab | ||||||
14 | External server connection | Set the checkbox | Defines if Intellect connects to the external supserver using the PS-RTP Server object via the GB2818 GB28181 protocol | Boolean type | Clear | Set—the external server connection is enabled Clear—the external server connection is disabled |
15 | IP | Enter the value into the field | IP address of the supserver | IP address | - | 000.000.000.000 – 255.255.255.255 |
16 | Port | Enter the value into the field | Port used to connect to the external server | Sequence of numbers | 5060 | 0–65535 |
17 | Transport | Select the value from the list | Transport protocol used to connect to the external server | Supported transport protocols | - | TCP, UPD |
18 | Password | Enter the value into the field | Password used to connect to the external server | Latin, Cyrillic and service characters | - | A line containing a sequence of any characters |
19 | Login | Enter the value into the field | Username used to connect to the external server | Latin, Cyrillic and service characters | - | A line containing a sequence of any characters |
20 | Server ID | Enter the value into the field | The identifier of the supserver via the GB28181 protocol | Sequence of numbers | - | 00000000000000000000 – 99999999999999999999 |
...