Note
titleAttention!
Every time when ATM - Intellect Pro starts, it checks for a Backup folder at the root of the disk on which Intellect software is installed. This folder is created if it does not exist already. Do not  It is forbidden to delete this folder. 


Info
titleNote

ATM Intellect components (ATM Intellect Pro, ATM Intellect Workstation and ATM Intellect Workstation TC) can work in a distributed configuration, while all the listed objects see where each of them is installed and can be configured.

To create necessary ATM Intellect Pro objects, do the followingObjects creation in the hardware tree is performed as follows:

  1. Go to the Hardware tab of the System settings dialog box.
  2. Create the IIDK Interface object (1). Set the ID number identifier of the IIDK Interface object (2).
  3. Then create Create the ATM-Intellect Pro object based on the Computer object (1). After the ATM-Intellect Pro object is created, it can be configured. In the IIDK interface field enter the identification number of the IIDK interface object created on step 2.
    Image Removed On the settings panel of this object, in the IIDK interface field (2), enter the identifier of the previously created IIDK Interface object.
    Image Added
  4. Create the required number of child Surveillance Object objects on the basis of

    Then create one or more child Surveillance Object objects for

    the ATM-Intellect Pro object.
    Image Modified

    Info
    titleNote

    The Surveillance Object object name cannot contain the following characters: underscore "_", backslash "\", angle brackets ">" and "<", single quote "'".


You also need to create Video Capture Device, Camera and Sensor objects corresponding to the connected equipment. Creation and configuration of these objects is described in the INTELLECT Software Package. Installing and configuring security system components.

Objects creation is completed.