Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

In the Axxon One software  software package, several types of detection tools process incoming data:

  1. Motion in area detection.
  2. Situation analysis Scene analytics detection tools.
  3. Face detection.
  4. Automatic number plate recognition tool.
  5. Fire detection and smoke detection.
  6. Pose detection.Equipment detection (PPE
  7. )Personal protective equipment detection tools.
  8. Retail analytics.
  9. Water level detection.
  10. Service detection tools:
    1. Video detection.
    2. Audio detection.
  11. Neurocounter. 
  12. Detection tools embedded in a video camera.

Detection tools are configured using the   Detection Tools  tab interface (within the  Settings  tab). To configure detection tools, it is necessary to have the appropriate user rights.

When configuring the detection, in the Mode the Mode field, select NVIDIA GPU one by one. 

If only one NVIDIA GPU is installed, in the Mode the Mode field select select Nvidia GPU 0.
Image Modified

If more than one NVIDIA GPU is installed, in the Mode the Mode field select the video card which should be used for detection.

It is possible to change the order of NVIDIA GPUs display using the CUDA_DEVICE_ORDER system variable (see Appendix 10. Creating system variable) by specifying the required value:

  1. The FASTEST_FIRST value numbers the GPUs from the most powerful card to the less powerful ones, i.e. GPU 0 is  is the most powerful card.
  2. The PCI_BUS_ID value numbers the GPUs according to the physical location of the cards in the PCI-E slots on the motherboard, i.e. GPU 0 is the card in the highest slot.

To find out information about the availability, quantity and numbering of NVIDIA GPUs, do the the following: 

  1. Run a command line as an administrator.
  2. In the command line type the nvidia-smi query.
  3. Press Press Enter.

The command line window will display information about the installed NVIDIA GPUs.
Image Modified

Note
titleAttention!

If you select a non-installed NVIDIA GPU in the  Mode  field, detection will not be performed.

For a video camera and its corresponding branch to appear in the detection tools list, the camera should be enabled in

...

Axxon

...

One.

Info
titleNote

By default, camera inputs that can be activated through an automatic rule are displayed in on the list of detection tools list.

In the viewing tile, on the right side of the detection configuration window, you can set visual parameters. 

...

The default system setting to a detection event is not to trigger any response actions. To set system response, create an automatic rule or a macro (see Configuring Create MacrosAutomatic Rules).