Integrated IP devices

To check whether the required IP device is integrated into Axxon PSIM, do the following:

  1. Go to the Documentation Drivers Pack page page.
  2. Download the list of supported IP devices (the latest release) in the xls XLS format.
  3. Open the file and go to the Axxon PSIM tab. 
  4. If the IP device is present in the list and the specified firmware in the file is the same as the current device firmware, it means the device is integrated.    

    Tip

    The full article: Complete guide Camera discovery tool


  5. If the IP device is not present in the list but it is known that it supports some common protocols (General device, ONVIF, RTSP), connect the device via these protocols:
    1. The General device generic drivers allow the AxxonSoft products to practically operate with all the devices of the corresponding vendor.

      Tip

      The full article: Complete guide Using Generic Drivers (General device, generic)


    2. Before connecting via the ONVIF protocol, check the device operation in the ONVIF Device Manager utility. If you can get the IP device video in this utility, then the device can be connected to Axxon PSIM.

      Tip

      The full article: Complete guide Connecting devices via the ONVIF protocol


    3. Before connecting via the RTSP protocol, check the device operation in the VLC Media Player utility. If you can get the IP device video in this utility, then you can connect the device to Axxon PSIM.

      Tip

      The full article: Complete guide Configuring multimedia receipt using RTSP protocol


Integrated ACS/FSA/PIDS

To check whether the required Access Control System (ACS), Fire Security Alarm (FSA) and Perimeter Intruder Detection System (PIDS) are integrated into Axxon PSIM, go to the ACFA PSIM List list of Integrated Equipmentintegrated equipment page and find the required system in the list.

The integrated systems connection setting is described in the documentation on the corresponding integration module. The full list of documents is available on the page.

If the system is not present in the list but it is known that it supports the general-purpose protocols (OPC, BACnet, SNMP), connect this system via these protocols.

Tip

The full article: Complete guide General-purpose protocols integration modules

Integrated cash register system and truck scales

To check whether the required cash register system or truck scales are integrated to POS -Axxon PSIM, go to the Equipment/Hardware integrated into the POS -Intellect SoftwarePSIM software page and find the required system in the list.

If the system is not present in the list, the connection setting is executed on the POS-terminal object setup panel.

Tip

The full article: Complete guide Selecting the type of POS - terminal type and setting the connection parameters

If the system is not present in the list, you can put in a request for integration.

Tip

The full article: Complete guide How to integrate a new POS - terminal into POS IntellectPSIM