Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

By default, a single Video surveillance monitor displays all Surveillance windows related to it. The buttons on the top left side of the tools panel toolbar are used for changing the number of surveillance the Surveillance windows displayed on the Video surveillance monitor.

Info
titleNote

If the display of the Control panel is disabled (see Setting the parameters of the Monitor interface boxwindow), then the Surveillance the Surveillance windows will be positioned automatically in such a way as to fill the area of the Monitor interface window. Moreover, if the the Keep camera ratio parameter is disabled, then the video image in the Surveillance windows will be "stretched" or "compressed" to the width of the Monitor interface window.

The one-fold button  button is used to display a single selected Surveillance window, the other buttons are used to simultaneously display a certain number of windows (4, 6, 9 or 16)  on on the Video surveillance monitor.  The The set of displayed buttons changes automatically depending on the maximum number of video cameras corresponding to the this Video surveillance monitor.

There is a special layout with 6 Video six Surveillance Windows windows featuring one Video Surveillance Window window larger than other five. This layout has certain restrictions mentioned below. The special six windows -fold layout can only be displayed by the  button while the Tools panel button if the toolbar is enabled in the Video Surveillance Monitorsurveillance monitor. See pictures the figures below for examples of the six windows -fold layout with and without the Tools panelthe toolbar enabled and disabled.

Double left clicking click in the Surveillance window on any layout, except for the six layouts-fold layout, allows increasing the size of the Surveillance window, while some Surveillance windows will be hidden on the Video surveillance monitor. Double right clicking click on the video image allows returing to the original layout.

The mouse control for Managing the number of the Surveillance windows number with the mouse can be altered changed with the registry keys (see Registry keys reference guide). When using the MaximizeCameraOnDblClk registry keydouble left clicking click switches the Surveillance window to the single one-fold layout mode from any layout, including the six-fold layout mode. Also, the transfer switching to the one-window fold layout and backwards back can be enabled with the UseOneClkToMaximizeOrMinimizeCamera key.

...

Key valuesAction on mouse double - click

MaximizeCameraOnDblClk = 0
MinimizeCameraOnDblClk = 0 or 1

UseOneClkToMaximizeOrMinimizeCamera = 0 or 1

Standard behavior, the window size does not number of the windows doesn't increase in the six-fold layout mode.

MaximizeCameraOnDblClk = 1
MinimizeCameraOnDblClk = 0

UseOneClkToMaximizeOrMinimizeCamera = 0 or 1

The six-fold layout mode is switched switches to the single layout mode on one-fold layout with left double -click, six layout mode is switched to the smaller window size on right double-click.click. The one-fold layout switches to the six-fold layout with right double click

MaximizeCameraOnDblClk = 1
MinimizeCameraOnDblClk = 1

UseOneClkToMaximizeOrMinimizeCamera = 0

The window size is switched to the single layout mode on left double-click, the window size is switched to the smaller window size on current layout switches to the one-fold layout with left double click. The layout switches to the smaller window size with right or left double - click.

MaximizeCameraOnDblClk = 1
MinimizeCameraOnDblClk = 1

UseOneClkToMaximizeOrMinimizeCamera = 1

The window size is switched to the single layout mode on current layout switches to the one-fold layout with left or right click, . The layout switches to the smaller window size is switched to the smaller window size on with right or left click.

Note. The first mouse click of the mouse button in the Surveillance window activates enables the camera, so if the window is not isn't initially active, two clicks will be required to enlarge.

In addition, the number of video surveillance the Surveillance windows can be changed using the custom layouts - (see Windows layout on the monitor). However, the left double - click always increases enlarges the viewing Surveillance window to the full-screen single layout modeentire Video surveillance monitor. Moreover, if the user custom layout is selected, the layout mode buttons icons are disabled, regardless of the number of the Surveillance windows displayed on the selected layout.

If GreenStream is configured (see Configuring an auto select automatic selection of video stream for displayingdisplay), then when changing the number of the Surveillance windows and scaling the video image, the video streams used for their display can be automatically changed.

Info
titleNote.

The Monitor tools panel Video surveillance monitor toolbar can be disabled due to unavailable if the system setupis configured accordingly.

If the Overlay 1 mode is enabled during the system setupconfiguration, then the surveillance Surveillance window scaling by left double -clicking click is disabled, and the surveillance Surveillance windows layout cannot be changed.

...