Go to documentation repository
...
The settings panel of the Control panel object is shown in the figure.
Table The table describes the parameters of the settings corresponding to the elements of the settings panel of the Control panel object.
№
| Parameter | Method for setting the parameter value | Parameter description |
Representation | Default value | Value range | |
1 | The Identification number* | Automatically | Displays the identification number of the Control panel object in the |
video surveillance system with |
distributed architecture |
Sequence of numbers
Digits, letters, periods, hyphen, dash, and underscore | NA |
Depends on the number of the Control panel objects in the |
video surveillance system with |
distributed architecture | ||
2 | The Name* | Enter the value |
in the field | Sets the name of the Control panel object in the |
video surveillance system with |
distributed architecture | Latin alphabet, Cyrillic |
and service characters | Control panel | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | The Disable | Set the checkbox |
Disables the Control panel object |
in the |
video surveillance system with |
distributed architecture | Boolean type | Clear | Set—the Control panel object is disabled and isn't used Clear—the Control panel object is enabled and is used |
4 | The Telemetry Controller | Select the value from the list | Sets the Telemetry Controller parent object of the |
system with |
distributed architecture |
to which the |
given Control panel object belongs |
Names of |
the Telemetry Controller objects registered in the system | Name of the Telemetry Controller parent object | Depends on the number of telemetry controllers in the |
video surveillance system with |
distributed architecture | ||||||
The Settings group | ||||||
5 | The Port | Select the value from the list | Sets the number of the computer serial (COM) port used to connect the |
control panel | List of available COM ports | COM1 | Depends on the number of COM ports on the |
server or Remote Administrator's workstation |
6 |
The Rate | Select the value from the list | Sets the data communication speed |
via the serial (COM) port | Kb/s | 9600 | From 300 to 256000 |
7 | The Parity | Select the value from the list | Sets the parity check mode for the data transmission over the serial (COM) port |
Names of the parity check modes | None | Even, Odd, None, Mark, Space |
8 | The DTR checkbox | Set the checkbox |
Enables power supply to the |
control panel via the output of the serial DTR |
(COM) port | Boolean type | Set | Set—the power |
is supplied via the DTR port output Clear—the power |
isn't supplied via the DTR port output | ||
9 | The RTS | Set the checkbox |
Enables power supply to the |
control panel via the output of the serial RTS |
(COM) port | Boolean type | Set | Set |
—the power |
is supplied |
via the RTS port output Clear |
—the power isn't supplied via the RTSport output | |||
10 | The Priority | Select the value from the list | Sets the priority |
for controlling the PTZ devices via the control |
panel | Names of priorities used to control the PTZ devices | Low |
|
|
|
|
|
|
|
|
*Name of the element is not isn't displayed in the settings panel of the given object.