The tweaki.exe utility is designed used for configuring the Axxon PSIM system by editing the sections of the Windows registry, where the setup parameters for the Axxon PSIM core and modules are stored:

  • For 64-bit systems, the sections are HKLM\SOFTWARE\Wow6432Node\AxxonSoft and HKCU\SOFTWARE\Wow6432Node\AxxonSoft.
  • For 32-bit systems, the sections are HKLM\SOFTWARE\AxxonSoft and HKCU\SOFTWARE\AxxonSoft.

The utility should be run as the same Windows user who is used to start Axxon PSIM, otherwise the new settings may not apply. This is because the choice of the Windows account determines to which registry section the changes will be written.

Info
titleAttention!
Specifying invalid Invalid values of the registry keys may lead to the system failure.

The Tweakitweaki.exe utility provides the following functionality:

  1. Setup of Axxon PSIM system start-up startup (see The Settings panel of the Windows section);
  2. Enabling the debug mode of Axxon PSIM (see Selecting Enabling and enabling configuring the debug mode of Axxon PSIM software);
  3. Advanced setup setting of the video Video surveillance monitor (see The Settings panel of the Video subsystem section);
  4. Advanced setup setting of events logging (see The Settings panel of the Axxon PSIM section);
  5. Advanced setup setting of video signal processing by Server (see The Settings panel of the Video subsystem section);
  6. Advanced setup setting of distributed architecture (see Extended setup of the distributed architecture);
  7. Changing netnames network names and IP-addresses in the configuration database (see Changing computer names and IP addresses in the Axxon PSIM configuration database);
  8. Limiting the RAM used by MS SQL server (see Limiting memory usage by an MS SQL server);
  9. Advanced setup setting of audio or video recording to an archive (see The Settings panel of the Video subsystem section);
  10. Re-indexing audio and video archives (see Re-indexing the audio and video recordings archive);
  11. Selecting the analog video out output operation mode The Settings panel of the Video subsystem section);
  12. Testing the operability of video capture cards (see Testing video capture cards);
  13. Advanced setup setting of PTZ devices (see The Settings panel of the PTZ section);
  14. Advanced setup setting of POS -Axxon PSIM (see The Settings panel of the POS PSIM section);
  15. Displaying versions of Axxon PSIM modules (see The Settings panel of the Version section).