Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The POS process system object is created under on the basis of the Computer object in on the Hardware tab of the System setting dialog box.  

 Image Modified

To configure the POS process system object, do the following:

  1. Go to the settings panel of the POS process object.
    Image Modified
  2. The POS terminal objects created in the object objects tree are listed in the Available POS terminals list (1).
  3. Move the required terminals to the Selected POS terminals (2) using the  and Image Removed buttons (2). Information and Image Added buttons. The information from selected terminals will be in use used to count cases the occurrence of appearing the specified parameter.

    Info
    titleNote.
     To back To move the POS terminals from the Selected POS terminals list to the Available POS terminals list, use the  and  buttons.


  4. In the Parameter name field, enter the name of the parameter at which , the number of equal values is to be controlled the same values of which should be monitored (3). Parameter The parameter name is depends on protocol characteristics on which the characteristics of the protocol used by the terminal works.
  5. In the Maximal number field, enter the maximal maximum number of occurrence of appearance the same values of equal the parameter values (4).
  6. In the Additional information field, enter the events description which will be included to in the event description next to the card number and number of repeats repetitions (5).
     

    Info
    titleNote.
    In the example displayed in the figure, the description of alarm messages will be presented as «Some information 3x123», where 123 is a card number, 3 is a number of times when the parameter appearedoccurred.


  7. From the Clear counter by time zone activation drop-down list, select the Time zoneschedule object corresponding to the time period, the start of which shows indicates the necessity to reset the counter of parameter appearances occurrence (6).
     

    Info
    titleNote.
    The Time zoneschedule objects are created and configured on the Programming tab of the System setting dialog box. Detail For more information about creating and configuring the time zone is presented in the Axxon PSIM software package. , see Administrator’s Guide document.


  8. Click the Apply button (7).

Configuration of the POS process system object is completed.