Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Section
Column
width50%
Panel
borderColor#CCCCCC
bgColor#FFFFFF
titleBGColor#F0F0F0
borderStylesolid
titleOn the page:

Table of Contents


Column


Configuring the parameters

...

To configure the Close-standing people detectiondetector, do the following:

  1. Create
  2.  Pose Detection (see Configuring the Pose Detection
  3. the Human pose detector (see Configuring the Human pose detector).
  4. Below the
  5.  Pose Detection, click 
  6. Human pose detector, click Create… Close-standing people
  7. detection
  8. detector.

By default, the Close-standing people detection triggers detector generates an event when "skeleton" bounding boxes around people collide. 

Info
titleNote

Bounding boxes are not displayed in the interface. They are usually a bit larger than the "skeletons" dimensions.

If necessary, you can change the detection tool detector parameters. The list of parameters is given in the table:

ParameterValueDescription
Other
EnableYesThe detection tool detector is enabled by default. To disable the detection tooldetector, select the the No value value
No
NameClose-standing people detectiondetectorEnter the detection tool detector name or leave the default name
TypeClose-standing people detectiondetectorName of the detection tool detector type (non-editable field)
Basic settings
Distance sensitivity2Specify the distance between people in meters at which the detection tool must trigger. Alarm will be detector must generate an event. An event is generated if the distance between people in the frame is equal to or less than the specified distance. The value must be in the range [0, 20]
Leveling rod length1.7Specify the average height of a person in meters, according to which the leveling rods are set. The value must be in the range [0 3]
Number of measurements in a row to trigger detection4Specify the minimum number of frames with close-standing people for the detection tool to trigger. detector to generate an event. The value must be in the range [1, 100].
Increasing the value can help eliminate false
alarmsevent, but increases the risk of skips. 
Decreasing the value can help reduce skips,
but increases but increases the probability of false alarmsevents

To save the parameters of the detection tooldetector, click the Apply Apply Image Modified button. To cancel the changes, click the Cancel Cancel Image Modified button button.

Configuring the frame perspective 

if If you want to change the triggering distance that must generate an event, you must configure the frame perspective:

Note
titleAttention!

For portrait-oriented scenes (such as corridor, shopping aisle, warehouse aisle, and so on), we recommend configuring the perspective in any case.

  1. In the preview window, click
  2. the 
  3. the Image Modified
  4.  button
  5.  button.
  6. Specify the size of the same object in different parts of the frame by eye
  7. .
  8. :
    • To create a leveling rod, left-click the video image to add two anchor points.
  9. You must set
    • Set at least three

  10. leveling rods. 
    • calibration rods. The lower anchor points of any three rods must not be located on the same line (horizontal, vertical, slanting, and so on).

    • The size of the leveling rod must be about the average height of a person at this part of the frame.
    • You can resize the rod by stretching its anchor
  11. points 
    • points Image Modified. You can move it on screen
  12. by 
    • by dragging and dropping.
      Image Modified
      Note
      titleAttention!

      When you set up leveling rods, the following conditions must be met:

      1. the rods that are located at the same distance from the camera lens
  13. ,
      1. must be of the same size;
      2. the feet of the rods must be located on the same surface (for example, floor);
      3. in complex scenes, we recommend adding more than three rods to increase the accuracy of the detection;

      4. in the parts of the frame where the lens vertical distortion is observed, the rods must be parallel to the nearest vertical objects (for example, door

  14. ,
      1. or wardrobe);

      2. for portrait-oriented scenes (such as corridor, shopping aisle, warehouse aisle, and so on), the arrangement of the rods must form triangles.
      Info
      titleNote
      • For convenience of configuration, you can "freeze" the frame. Click
  15. the 
      • the Image Modified
  16.  button
      •  button. To cancel the action, click this button again.
      • The area for detection is displayed by default. To hide it, click
  17. the 
      • the Image Modified
  18.  button
      •  button. To cancel the action, click this button again.
      • To delete a rod, click
  19. the 
      • the Image Modified
  20.  button
      •  button.

  21. Click
  22. the Apply button
  23. the Apply button.

Configuration of the Close-standing people detector is complete.