The face of the settings panel for of the Monitor object is shown in the figures.

The settings panel of the Monitor object. The Basic settings tab.

...

Image Modified

The settings panel of the Monitor object. The List of cameras tab.

 Image Modified

The settings panel of the Monitor object. The PTZ tab.

Image Modified

The Interface tab.

Image Added

Table table describes the setting parameters of the Monitor interface object.


 

 

Parameter

Method

of

for setting the parameter value

Parameter description

Symbols used

Representation

Default value

Value range

1

The

Identification number

field

Automatically

Displays the identification number of the Monitor interface object in the system

.Sequence of numbers

Numbers, letters, periods, hyphen, dash and underscore

-

Depends on the number of the Monitor objects in the system

.

2

The

Name

field

Enter the value

in

into the field

Defines

Sets the name of the Monitor object in the system

.

Latin, Cyrillic and service

digits

characters

Monitor

A line containing a sequence of any

symbols

characters (letters, digits, service characters

apart from

except > and <

symbols

characters),

not

case-

sensitive

insensitive.

Number of

symbols –

charactersfrom 1 to 60

.

3

The

Disable

checkbox

Set the checkbox

Defines the mode of the Monitor object

Sets the state (enabled or disabled)of the Monitor object in the system

.

Boolean type

-

Clear

Yes

Setthe Monitor object is disabled and

is not in use

isn't used

Clear

No

the Monitor object is enabled and

is in use

used

4

The

Display

drop-down list

Select

in

the value from the list

Sets the Display parent

Display

object

 for

for the given Monitor object

.

Names of the Display objects registered in the system

Name of the Display parent

Display

object

Depends on the number of the Display

object s

objects in the system

.

The Coordinates group

5

The

X

field

Enter the value

in

into the field

Set

Sets the X coordinate in the horizontal axis for the upper

-

left corner of the Monitor interface

box

window

% of the screen width

-

From 0 to M*100, where M is the number of the installed computer monitors

installed

6

The

Y

field

Enter the value

in

into the field

Set

Sets the Y coordinate in the vertical axis for the upper left corner of the Monitor interface

box

window

% of the screen height

-

From 0 to M*100, where M is the number of the installed computer monitors

installed

7

The

W

field

Enter the value

in

into the field

Set

Sets the width of the Monitor interface

box

window

% of the screen width

-

From 20 to 900 if control panel is enabled. Otherwise, from 0 to 900.

This restriction can be

removed

disabled using the UnlimitMonitorSize registry key (see Registry keys reference guide)

.

8

The

H

field

Enter the value

in

into the field

Set

Sets the height of the Monitor object if the control panel is

not active

disabled

% of the screen width

-

From 0 to 900.

This restriction can be

removed

disabled using the UnlimitMonitorSize registry key (see Registry keys reference guide)

.

9

The

Monitor

drop-down list

Select

in

the value from the list

Sets the number of the physical monitor

number

, the coordinates

to

for which are

assigned

Sequence of numbers

1

From 1 to 9

set. The monitors are numbered in the order of their physical location from left to right, from top to bottom. The 1st monitor is the one in the upper left corner regardless of which monitor is set as main or what number the monitor has in OS.

In the figure below, the monitor numbers in OS are given in gray while the numbers in Intellect are red.

Image Added

Attention! It is recommended to set the same resolution for all monitors in the system. Different resolution is only allowed if all monitors are aligned along any border (for example, upper border)

Sequence of numbers

1

From 1 to 16

10

Allow moving

Set the checkbox

Allows moving the the Monitor interface window manually, if the control panel is enabled

Boolean type

Clear

Set—the manual moving is allowed

ClearSet—the manual moving isn't allowed

11The X buttonClick the buttonOpens the window for specifying the position of the Monitor interface window---
The Quad splitter group
12horizontalEnter the value into the field

Sets the number of the surveillance windows that should be displayed horizontally on the Monitor. If value is not specified (the field is blank), then the default grid of the surveillance windows depending on the selected layout is displayed

Sequence of numbers-From 1 to 64
13verticalEnter the value into the field

Sets the number of the surveillance windows that should be displayed vertically on the Monitor. If value is not specified (the field is blank), then the default grid of the surveillance windows depending on the selected layout is displayed

10

The Allow moving checkbox

Set the checkbox

Allows hand shifting of the Monitor interface box if the control panel is active

Boolean type

-

Yes – hand shifting is allowed.

No – hand shifting is prohibited.

Quad splitter group11horizontal fieldEnter the value in the fieldSets number of video surveillance windows in the horizontal direction to display then on the Monitor. If value is not specified (field is empty) then default grid of video surveillance windows depending on the selected layout is displayedNatural numbers->012vertical fieldEnter the value in the fieldSets number of video surveillance windows in the vertical direction to display then on the Monitor. If value is not specified (field is empty) then default grid of video surveillance windows depending on the selected layout is displayedNatural numbers->0

The Basic settings tab

13

The Overlay drop-down list

Select in the list

Set the Overlay mode for processing video signals

Names of overlay modes

Method2 (Recommended)

Method1 – video signals are processed as one stream

Method2 (Recommended) – video signals are processed independently from each other

None – video signals are not processed by a video capture card

14

The Active camera switch

Set in the position

Set the display mode for an active camera box

Boolean type

-

Yes - The Active camera mode is enabled and is in use

 No - The Active camera mode is disabled and is not in use

15

The Alarms cameras switch

Set in the position

Set the display mode for alarm cameras’ boxes

Boolean type

-

Yes - The Alarms cameras mode is enabled and is in use

No - The Alarms cameras mode is disabled and is not in use

16

The Max field

Enter the value in the field

Specify the maximum number of video cameras, boxes of which are displayed on the Monitor in the Alarms cameras and List modes

Sequence of numbers-From 1 to 64

Depends on the number of cameras registered in the system

17

The Min field

Enter the value in the box

Specify the minimum number of video cameras, boxes of which are displayed on the Monitor in the Alarms cameras even on no-alarm

Sequence of numbers

-

From 1 to 64

Depends on the number of cameras registered in the system.

0 – on no-alarm camera boxes are not displayed in the Monitor box.

18

The List switch

Set in the position

Set the display mode according to the selected layout.

Boolean type

Yes

Yes - The List mode is enabled and is in use

No - The List mode is disabled and is not in use

19

The Control panel checkbox

Set the checkbox

Activates the control panel for the Monitor in the List mode

Boolean type

-

Yes - The Control panel mode is enabled and is in use

No - The Control panel mode is disabled and is not in use

20

The Telemetry control drop-down list

Select in the list

Set the prioritiy for the Telemetry control using the Monitor object

Names of the Telemetry control priorities

Low priority

Forbidden – option of the Telemetry control using the Monitor object is disabled

Low priority – low priority of control

High priority – high priority of control

21

The Slideshow field

Enter the value in the field

Set the period of automatic slideshow of camera boxes when the control panel is enabled

Period in seconds (s)

-

Whole number from 1 and bigger

22

The 4:3 Ratio checkbox

Set the checkbox

Set the 4:3 proportion of height and width of the Monitor box

Boolean type

-

Yes - proportion of height and width of the Monitor box is 4:3

No - proportion of height and width of the Monitor box can be random.

23

The Show captions checkbox

Set the checkbox

Shows the captions for cameras of the Monitor interface box.

In large distributed systems it is recommended to disable captions on those monitors where captions are not planned to be shown in order to decrease the number of redundant events.

Boolean type

Yes

Yes – The Captions submenu is available  in the context menu of the Monitor interface box

No – The Captions submenu is unavailable  in the context menu of the Monitor interface box

 

24Smoothing checkboxSetting checkbox

Is used when it is required to display video with greater resolution on which the ladder effect appears while displaying in the small window

Note. When this feature is enabled, the CPU load of the computer where the display is performed increases. It is recommended to use only to display video from analog cameras or low-resolution video.

Boolean typeNo

Yes – smotthing is applied.

No – smoothing is not applied

25

The Audio player drop-down list

Select in the list

Sets the Audio player object used to playback audio signals and export video with audio from the Monitor interface

Names of the Audio player objects registered in the system

-

Depends on the number of the audio players registered in the system

26Group of checkboxes used to enable displaying elements of Surveillance windows Set the checkboxesAllows enabling and disabling display of various elements of the Surveillance window such as number, name, time, menu and camera frame as well as additional info on the camera.Boolean typeAll checkboxes are set checked

Yes – the corresponding element is displayed in Surveillance windows of all cameras added to the Video surveillance monitor.

No – the corresponding element is not displayed in Surveillance windows on the Video surveillance monitor.

The List of cameras tab

27

The Number drop-down list

Select in the list

Set the number of the video camera to display on the Monitor

Sequence of numbers

-

Depends on the number of video cameras registered in the system

28

The Camera drop-down list

Select in the list

Set the name of the video camera to display on the Monitor

Name of the cameras registered in the system

-

Depends on the number of video cameras registered in the system

29

Video stream drop-down list

Select value from the list

 Set the number of video stream from camera which is to be displayed when receiving video stream straight from camera

Streams numbers

Default

1, 2, 3, 4 – video streams.

Default – default video stream.

30

Connection drop-down list

Select value from the list

Set the way of receiving video from camera

Ways of receiving video

Through Server

Direct - the video stream is received straight from camera

Through Server - the video stream is received from the Server, which camera is connected to

31

The Fps drop-down list

Select in the list

Set the fps for transmitting the video signal to the Monitor of the Client.

Sequence of numbers

-

1, 2, 3, 4, 6, 8, 12, 16, 20, 25, 30

32

The Compression drop-down list

Select in the list

Set the compression for transmitting the video signal to the Monitor of the Client.  The given value leads to extra consumption of Server’s resources.

Sequence of numbers

-

In the range of rising compression level 0,1,2,3,4,5

0 – the video signal is not compressed

5 – maximum compression of the video signal

33

Compressor drop-down list

Select value from the list

Specifies the procedure of video stream compression which is in use for video signal recompression for displaying on the Monitor. The value is to be selected in the Compression list if the compressor is specified.

List of available procedures

-

MJPEG, Motion Wavelet 3.5, Motion Wavelet 7.1

34

The Gate drop-down list

Select in the list

Set the Gate object via which the live and archive video from the selected camera is to be transmitted to the Monitor

Names of the Gateway objects registered in the system

-

Depends on the number of the Gate objects registered in the system

35

The Backup archive drop-down list

Select in the list

Set the Backup archive object the video archive fromthe selected camera of which is to be transmitted to the Monitor

The Basic settings tab

14

Display

Select the value from the list

Sets the mode for processing the video signals from the video cameras by the graphics card

Names of the display modes

DirectDraw (Recommended)

Direct3D is used when it is necessary to display the video from the fisheye cameras or the signal decoded using Intel QuickSync technology

DirectDraw (Recommended) is used by default in all other cases

Programmedvideo signals are not processed by the graphics card

15

Active camera

Set the radio button

Sets the display mode for an active camera window only

Boolean type

Clear

Setthe Active camera mode is enabled and used

Clear—the Active camera mode is disabled and isn't used

16

Alarm cameras

Set the radio button

Sets the display mode for alarm cameras windows

Boolean type

Clear

Setthe Alarm cameras mode is enabled and used

Clear—the Alarm cameras mode is disabled and isn't used

17

Max

Enter the value into the field

Sets the maximum number of the video cameras windows that can be simultaneously displayed on the Monitor in the Alarm cameras and List modes. If the number of alarm cameras is greater than the maximum number, the Monitor will display the number of cameras specified in the Max field

An integer greater than zero (for example, 1, 2, 50)

-

Depends on the number of the cameras registered in the system. There are no restrictions on the number of cameras

18

Min

Enter the value into the field

Sets the minimum number of video cameras windows that can be displayed on the Monitor in the Alarm camers mode. If the number of the alarm cameras is less than the minimum number, the Monitor will display fewer cameras than specified in the Min field. At the same time, the Monitor fold will remain consistent with the Min field

An integer from zero and greater (for example, 1, 2, 50)

-

Depends on the number of the cameras registered in the system. There are no restrictions on the number of cameras.

0—when there are no alarms, the camera windows aren't displayed in the Monitor window

19

List

Set the radio button

Set the display mode of the surveillance windows according to the selected layout

Boolean type

Set

Set—the List mode is enabled and used

Clearthe List mode is disabled and isn't used

20

Control panel

Set the checkbox

Enables the display of the toolbar on the Monitor in the List mode

Boolean type

Clear

Setthecontrol panel is enabled and used

Clearthe control panel is disabled and isn't used

21

PTZ control

Select the value from the list

Sets the priority to control the PTZ devices using the Monitor object

Names of the PTZ devices control priorities

Low priority

Forbidden—the option of the PTZ control using the Monitor object is disabled

Low prioritylow priority of control

Normal priority—medium priority of control

High priorityhigh priority of control

22

Slideshow

Enter the value into the field

Sets the period of the automatic slideshow of the camera windows when the control panel is enabled

Period in seconds (s)

Blank field

Blank field or 0the camera windows are scrolled every 3 seconds

An integer from 1 to 600the camera windows are scrolled at the specified interval

23

Keep camera ratio

Set the checkbox

Sets the ratio of the width and height of the video image in the surveillance windows on the Video surveillance monitor

Boolean type

Clear

Setthe ratio of the width and height of the video image corresponds to the ratio of the camera

Clearvideo image fits the entire area of the Surveillance window, while the ratio may be affected

24

Show captions

Set the checkbox

Shows the captions for the cameras of the Monitor interface window.

In large distributed systems it is recommended to disable captions on those monitors where captions are not planned to be shown

Boolean type

Set

Setthe Captions submenu is available in the context menu of the Monitor interface window

Clearthe Captions submenu is unavailable in the context menu of the Monitor interface window


25SmoothingSet the checkbox

It is used when it is required to display video with greater resolution on which the ladder effect appears when displaying in the small window.

Note. When this feature is enabled, the CPU load of the computer where the display is performed increases. It is recommended to use only to display video from analog cameras or low-resolution video

Boolean typeClear

Setsmoothing is applied

Clearsmoothing isn't applied

26

Audio player

Select the value from the list

Sets the Audio player object used to playback the audio signals and export video recordings with audio from the Monitor interface

Names of the Audio player objects registered in the system

-

Depends on the number of the Audio players registered in the system

27Group of checkboxes used to display the elements of the Surveillance windows Set the checkboxesAllows enabling and disabling the display of various elements of the Surveillance window such as number, name, time, menu, camera frame and additional info on the camera, as well as the name of Video surveillance monitorBoolean typeAll checkboxes are set except Additional info

Setthe corresponding element is displayed in the Surveillance windows of all cameras added to the Video surveillance monitor

Clearthe corresponding element isn't displayed in the Surveillance windows on the Video surveillance monitor

The List of cameras tab

28

Number

Select the value from the list

Sets the number of the video camera to display on the Monitor

Sequence of numbers

-

Depends on the number of the video cameras registered in the system

Camera

Select the value from the list

Sets the name of the video camera to display on the Monitor

Name of the cameras

Names of the Backup archive objects

registered in the system

-

Depends on the number of the

Backup archive objects

video cameras registered in the system

36

The External storage

Video stream

Select the value from

Select in

the list

Set the External storage object

Sets the number of the video

archive from which is to be transmitted to the Monitor via the selected camera

Names of the External storage objects registered in the system

-

Depends on the number of the External storage objects registered in the system

37

The Gateway for Backup archive drop-down list

Select in the list

Set the Gate object via which the video archive of the Backup archive object is to be  transmitted to the Monitor

Names of the Gateway objects registered in the system

-

Depends on the number of the Gateway objects registered in the system

38The Display type dropdown listSelect value in the listSets the type of conversion performed in the Surveillance window on the Video surveillance monitorSupported conversion typesPTZ

PTZ – virtual telemetry.

Panorama – panoramic view.

39

The Range button

Click the button

Select all cameras registered in the system to display on the Monitor

-

-

-

40

The All button

Click the button

Access to complex selection and editing of cameras’parameters to display on the Monitor

-

-

-

41

Auto select of streams for displaying checkbox

Setting checkbox

Enables the function of auto select of video stream for displaying in the Monitor. Influents on cameras for which the On default video stream is selected - see 25.

Boolean type

No

Yes - video stream for displaying is selected depending on the size of video image on the Monitor and required frame frequency

No -video stream is selected depending on the Video stream and Connection settings (25-26) and depending on settings of the Server and video camera from which the stream is required.

42

Mouse behavior

-

The list of available actions with a mouse

-

-

-

43

Action drop-down list

Select value from the list

Specify reaction performed while executing the corresponding action using a mouse

Reaction list of the PTZ device object

(Default)

Reaction list of the PTZ device object

44

Parameter field

Enter the value in the field

Specify the value of reaction parameter if it’s required

Depends on the selected action

-

Depends on the selected action. It is a preset number for reactions connected with presets, for other reactions it is speed if the selected reaction allows speed specifying as parameter. The speed value from the PTZ device object connected with Camera selected in the Monitor is in use if the parameter is not specified.

45

Joystick buttons column

-

List of joystick buttons

-

-

-

46

Action drop-down list

Select value from the list

Specify reaction which is to be performed while clicking the joystick button

List of reaction of PTZ device object.

(Default)

List of reaction of PTZ device object

 

47

Parameter field

Enter the value in the field.

Specify the value of reaction parameter if it is required.

Depends on the selected action

-

Depends on the selected action. It is a preset number for reactions connected with presets, for other reactions it is speed if the selected reaction allow speed specifying as parameter. The speed value from the PTZ device object connected with Camera selected in the Monitor is in use if the parameter is not specified.

stream displayed from the video camera when connected directly. If connected via the Server, this setting doesn't affect anything

Numbers of the video streams

Default

1, 2, 3, 4video streams numbers

Defaultdefault video stream

Connection 

Select the value from the list

Sets the way of receiving video image from the camera

Ways of receiving video

Through Server

Directthe video stream is received directly from the camera

Through Serverthe video stream is received from the Server, to which the camera is connected

fps

Select the value from the list

Set the FPS for transmitting the video signal to the Client Monitor

Sequence of numbers

-

1, 2, 3, 4, 6, 8, 12, 16, 20, 25, 30

Compression

Select the value from the list

Set the compression level for transmitting the video signal to the Client Monitor. The given value leads to extra consumption of Server resources

Sequence of numbers

-

In the order of increasing the compression level 0, 1, 2, 3, 4, 5

0the video signal is not compressed

5maximum compression of the video signal

Compressor

Select the value from the list

Sets the algorithm for the video stream compression which is used for the video signal recompression when displaying on the Monitor. If you set the compressor, you should also set the value in the Compression list

List of available algorithms

-

MJPEG, Motion Wavelet 3.5, MPEG4

Gate

Select the value from the list

Sets the Videogate object via which the live and archive video from the selected camera should be transmitted to the Monitor

Names of the Videogate objects registered in the system

-

Depends on the number of the Videogate objects registered in the system

Backup archive

Select the value from the list

Sets the Backup archive object from which the video archive from the selected camera should be transmitted to the Monitor

Names of the Backup archive objects registered in the system

-

Depends on the number of the Backup archive objects registered in the system

Edge storage

Select the value from the list

Sets the Edge storage object from which the video archive should be transmitted to the Monitor via the selected camera

Names of the Edge storage objects registered in the system

-

Depends on the number of the Edge storage objects registered in the system

Gateway for Backup archive

Select the value from the list

Sets the Videogate object via which the video archive of the Backup archive object should be transmitted to the Monitor

Names of the Videogate objects registered in the system

-

Depends on the number of the Videogate objects registered in the system

VMDA metadata storageSelect the value from the listSets the VMDA metadata storage object used for the forensic search in the archive of the corresponding cameraNames of the VMDA metadata storage objects registered in the system-Depends on the number of the VMDA metadata storage objects registered in the system
Type of displaySelect the value from the listSets the type of conversion performed in the Surveillance window on the Video surveillance monitorSupported conversion typesPTZ

PTZvirtual telemetry

Panoramapanoramic view

Macro1Select the value from the listSets the first macro to be displayed in the function menu of the camera in the Surveillance windowNames of the Macro objects registered in the system-Depends on the number of the Macro objects registered in the system
Macro2Select the value from the listSets the second macro to be displayed in the function menu of the camera in the Surveillance windowNames of the Macro objects registered in the system-Depends on the number of the Macro objects registered in the system
GuidAutomaticallyDisplays the unique identifier of the camera in the systemSequence of numbers, Latin and service characters-A line containing a sequence of any characters (letters, digits, service characters) enclosed in {curly brackets}

29

Range

Click the button

Access to complex selection and editing of cameras parameters to display on the Monitor

-

-

-

30

All

Click the button

Selects all cameras registered in the system to display on the Monitor

-

-

-

31

Automatic selection of streams for display

Set the checkbox

Enables the function of automatic selection of video stream for display on the Monitor. Affects cameras for which the On default video stream is selectedsee item 28

Boolean type

Clear

Setvideo stream for display is selected depending on the size of the video image on the Monitor and the required frame frequency

Clearvideo stream is selected depending on the Video stream and Connection settings and on the settings of the Server and video camera from which the stream is required

The PTZ tab

32

Mouse Behavior

-

The list of available actions with a mouse

-

-

-

33

Action

Select the value from the list

Sets the reaction performed when executing the corresponding action with a mouse

Reaction list of the PTZ device object

(Default)

Reaction list of the PTZ device object

34

Param.

Enter the value into the field

Sets the value of the reaction parameter if it’s required

Depends on the selected action

-

Depends on the selected reaction. For the reactions connected with the presets, it is a preset number. For other reactions, it is speed, if the selected reaction allows speed specifying as a parameter. If the parameter isn't specified, the speed value from the settings of the PTZ device object that is connected with the Camera seleected on the Monitor, is used

35

Joystick Butt.

-

List of joystick buttons

-

-

-

36

Action

Select the value from the list

Sets the reaction which should be performed when clicking the joystick button

List of reaction of the PTZ device object

(Default)

List of reaction of the PTZ device object


37

Param.

Enter the value into the field

Sets the value of the reaction parameter if it is required

Depends on the selected action

-

Depends on the selected reaction. For the reactions connected with the presets, it is a preset number. For other reactions, it is speed, if the selected reaction allows speed specifying as a parameter. If the parameter isn't specified, the speed value from the settings of the PTZ device object that is connected with the Camera seleected on the Monitor, is used

The Interface tab
38AlarmSelect the value from the list

Sets the frame color of the Surveillance window in the alarm state

RGB colorsRedRGB color palette
39ArmedSelect the value from the list

Sets the frame color of the Surveillance window when the camera is armed

RGB colorsYellowRGB color palette
40DisarmedSelect the value from the listSets the frame color of the Surveillance window when the camera is disarmedRGB colorsGreenRGB color palette
41No frame Select the value from the listSets the frame color of the Surveillance window when there is no frame in itRGB colorsBlackRGB color palette
42No signalSelect the value from the listSets the frame color of the Surveillance window when there is no signal from the cameraRGB colorsGreyRGB color palette
43Screen cacheSelect the value from the listSets the Surveillance window background color that is displayed when the video from the camera does not cover completely the Surveillance window, for example, when the camera proportions are maintainedRGB colorsPurpleRGB color palette
44Tracker frame color Select the value from the listSets the frame color to highlight the tracking objects on the video imageRGB colorsWhiteRGB color palette
45DefaultClick the button

Sets the default frame colors of the Surveillance window

---
46Hide capture framesSet the checkboxHides the frames displayed by the Face detection module when a person’s face is detected on the video imageBoolean typeClear

Setthe Face detection frames aren't displayed

Clearthe Face detection frames are displayed

47Over all windowsSet the checkboxEnables the display of the Video surveillance monitor on top of all windowsBoolean typeClear

Setthe Video surveillance monitor is displayed on top of all windows

Clearthe Video surveillance monitor is displayed in the default mode

48Camera switching dialogSet the checkboxEnables a special dialog for selecting a camera in the Surveillance windowBoolean typeClear

Seta special dialog is used for camera selection

Clearthe camera is selected in the function menu of the Surveillance window