The parameters of the Intellect settings panel are described in the table.
No | Parameter name |
Method of setting the parameter value | Description | Representation | Default value | Value range |
1 | The Core IP address field with |
button. |
Set on the Client |
Enter the value in the field/use the button |
Sets the IP address of the Intellect server to which the slave.exe module is connected by default. In case of pressing |
button, IP address of the local computer is set |
IP address | 127.0.0.1 | Depends on net settings of the Server. In case of connection failure dialog window requiring IP address is displayed | |
2 |
Keyboard prefix |
Enter the value in the field |
Sets the prefix for a special key-board. When a button is pressed on this key-board the Intellect detects when the button was pressed on this very key-board | Symbol |
— | Usually, a tilde (~), code 126 | |||||
The Logging subsystem group | ||||||
3 |
Debug mode |
Select the value from the drop |
-down list |
Sets the mode of the Intellect Debug window displaying | List of available modes of Debug window displaying | None | Disabled |
—Debug window is not displayed. Debug 1 |
—Debug window is displayed and a log-file containing recordings about modules errors is created. Debug 2 |
—Debug window is displayed and a log-file containing recordings about modules errors and alerts is created. Debug 3 |
—Debug window is displayed and a log-file containing recordings about all the modules events is created. Debug 4 |
—Debug window is displayed and a log-file containing recordings about all the modules events, and also additional menu that is individual for each module (used by programmers) are created |
4 |
Log-storing time (hours) |
Enter the value in the field |
Sets the time of keeping log files | Sequence | 48 hours | > 0 |
5 |
Counters logging time (sec) |
Enter the value in the field | Assigns the time interval in seconds for logging processor load, memory usage, and disk usage |
Sequence | 60 | Positive whole numbers not less than 60 and zero. If the value 0 is specified, sensor data is not included in the log file |
6 |
Save logs | Set the checkbox |
Checkbox
Enables logs saving | Boolean type | Yes | Yes |
—logs are saved. No |
—logs are not saved |
7 |
Redirect to debugger | Set the checkbox |
Enables the debugger | Boolean type | None | Yes |
—the debugger is in use. No |
—the debugger is not in use |
8 |
Maximum size (MB) |
Enter the value in the field | Defines the maximum size of RAM that log files can use. Log files are archived after that size is reached |
Sequence | 100 MB | >= 100 Values less than 100 Mb are ignored |
The JPG and AVI files export path group | ||||||
9 |
Default (Intellect\ |
Export)/Other |
Set in the position |
Sets the folder for exported |
frames from the Intellect video archive (see Frame export) |
— | Default (Intellect\Export) | Default (Intellect\Export) |
—exported to the C:\Users\%current user name%\Documents\Intellect\export\ folder |
Other—exported to the selected folder |
10 |
Other |
with the |
button | Click the button/ |
enter the value in the field |
Sets the |
path name to the folder, where |
frames from video archive are to be exported when the switch is set in the Other position |
Pathname
-
. Note. The specified path will be applied to the ExportDir registry key located in HKLM\SOFTWARE\WOW6432Node\AxxonSoft\Intellect\Video (see Registry keys reference guide) | Path name | — | — |
11 |
Open folder |
Click the button | Opens the current folder |
for frame export |
— |
— |
— |
12 |
Record path | Set the checkbox |
The checkbox |
allows you to prohibit changing the export directory when exporting an archive period
| Boolean type | No | Yes |
—export catalogue change is forbidden. |
No—export catalogue change is allowed |
No group | ||||||
13 |
Receive uncompressed video | Set the checkbox |
Checkbox
Enables receiving uncompressed video from the Server. As a rule is set on the Client | Boolean type | No | Yes |
—Client receives uncompressed video from the Server No |
—Client receives compressed video from the Server |
14 |
Event viewer over all windows | Set the checkbox |
Enable displaying the Event viewer window over all windows |
Boolean type | No | Yes |
—the Event viewer window is displayed over all windows. |
No—the Event viewer window is displayed if a corresponding screen is selected |
15 |
Only local protocol | Set the checkbox |
Enables logging the events registered in the given computer to the Events protocol database. Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section |
Boolean type | No | Yes |
—events registered in the given computer are recorded to the Events protocol database No |
—all required events are recorded to the Events protocol database |
16 |
Sort tree objects by ID | Set the checkbox |
Enables sorting of objects in the tree by identifier. Note 1. If sorting by name is |
chosen, and there are numbers in the object name, then the objects |
will be sorted in alphabetical order. For example, |
an object with the name "115" will be |
above the object with the name "15", because in the name "115" |
the second number is 1 |
, and in the name "15" |
the second number is 5. Note 2. This |
key also affects the sorting of objects in the tree when adding the objects to a layer in the Map |
Editor utility |
Boolean type | No | Yes |
—objects in the tree are sorted by identifier No |
—objects in the tree are sorted by name |
17 |
Disable protocol | Set the checkbox |
Disables events logging to the Event viewer database on this computer. Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section |
Boolean type | No | Yes |
—events are not logged to the Event viewer database No |
—events are logged to the Event viewer database |
18 |
Used memory dump | Set the checkbox |
Checkbox
Enables logging .dmp file with a copy of main memory with incorrect shutting down at least one of the system modules to the Intellect root folder | Boolean type | No | Yes |
—memory dump is created No |
—memory dump is not created |
19 |
Support old scripts | Set the checkbox |
Checkbox
Sets the support of program tools in Intellect | Boolean type | No | Yes |
—both scripts and programs are supported No |
—only scripts are supported |
20 |
Time synchronization | Set the checkbox |
Checkbox
Sets the time synchronization of all computers in the distributed system with system time of this computer. Time is automatically synchronized at midnight every 24 hours or when |
Intellect is started on the Server that is the source of time synchronization |
Boolean type | No | Yes |
—synchronization is enabled No |
—synchronization is disabled |
21 |
Overlay in Event protocol |
Select the value from the drop |
-down list |
Sets the overlay mode for processing the video signals that can be viewed with the help of the Event protocol object | Names of overlay modes | Overlay 2 | None |
—video signals are not processed by video card Overlay 1 |
—Direct3D is used Overlay 2 |
—DirectDraw is used |
22 |
Application language |
Select the value from the drop |
-down list |
Sets the Intellect Software System's interface language | Names of installed languages |
— | Depends on the set of installed languages. The process of installing languages is described in Intellect Software System's interface language |