Go to documentation repository
...
The settings panel of the Control panel object is shown in the figure.
Table The table describes the parameters of the settings corresponding to the elements of the settings panel of the Control panel object.
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range | |
1 | The Identification number* | Automatically | Displays the identification number of the Control panel object in the digitalvideo surveillance system with thedistributed architecture | Sequence of numbers | Digits, letters, periods, hyphen, dash, and underscore | NA - | Depends on the number of the Control panel objects in the digitalvideo surveillance system with thedistributed architecture |
2 | The Name* | Enter the value intoin the field | Sets the name of the Control panel object in the digitalvideo surveillance system with thedistributed architecture | Latin alphabet, Cyrillic charactersand service characters | Control panel | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 | |
3 | The Disable | Set the checkbox | Sets the state of the Disables the Control panel object (enabled or disabled)in the digitalvideo surveillance system with thedistributed architecture | Boolean type | Clear | Set—the Control panel object is disabled and isn't used Clear—the Control panel object is enabled and is used | |
4 | The Telemetry Controller | Select the value from the list | Sets the Telemetry Controller parent object of the digitalsystem with thedistributed architecture ,to which the givengiven Control panel object belongs | Name Names of thethe Telemetry Controller objects registered in the system | Name of the Telemetry Controller parent object | Depends on the number of telemetry controllers in the digitalvideo surveillance system with thedistributed architecture | |
The Settings group | |||||||
5 | The Port | Select the value from the list | Sets the number of the computer serial (COM) port used to connect the Controlcontrol panel | List of available COM ports | COM1 | Depends on the number of COM ports on the Serverserver or Remote Administrator's workstation | |
6 Speed | The Rate | Select the value from the list | Sets the data communication speed ofvia the serial (COM) port | Kb/s | 9600 | From 300 to 256000 | |
7 | The Parity | Select the value from the list | Sets the parity check mode for the data transmission over the serial (COM) port | List Names of the parity check modes | None | Even, Odd, None, Mark, Space | |
8 | The DTR checkbox | Set the checkbox | Sets whether or not the power should be supplied Enables power supply to the Control control panel via the output of the serial DTR serial (COM) port | Boolean type | Set | Set—the power will be is supplied via the DTR port output Clear—the power will not be isn't supplied via the DTR port output | |
9 | The RTS | Set the checkbox | Sets whether or not power should be supplied Enables power supply to the Control control panel via the output of the serial RTS serial (COM) port | Boolean type | Set | Set—the —the power will be is supplied via via the RTS port output Clear—the power will not be —the power isn't supplied via the RTSport output | |
10 | The Priority | Select the value from the list | Sets the priority of for controlling the PTZ devices via the control using the Control panel | Names of priorities used to control the PTZ devices | Low |
|
*Name of the element is not isn't displayed in the settings panel of the given object.