To configure the Web-Client, do the following:

  1. Click the Image Modified button in the top right corner and select Preferences.
  2. Image Removed
  3. Image Added
  4. By default, when you switch to another tab in the browser and minimize it, the video stream transmission stops. In order not to interrupt the video stream transmission, disable

  5. the 
  6. the Disconnect stream when inactive

  7. parameter 
  8. parameter (1). This setting is common to all Web-Client users in a particular browser.
    Image Modified

  9. By default,
  10. in the video
  11. if a layout with multiple cameras is open on the
  12. layouts
  13. screen,
  14. all
  15. only the reference frames are displayed
  16. . To reduce the load, you can disable the Show all frames parameter (2). As a result, on a layout with several video cameras, video playback will only be by key frames, and only when
  17. for all H.264 cameras. When you select a specific camera, all frames
  18. will be displayed. The parameter does not affect the archive video, as archive videos are always played back by all frames
  19. are displayed. If you want to display all frames of an H.264 video regardless of whether a camcorder is selected or not, enable the Show all frames parameter (2). This setting is common to all Web-Client users in a particular browser
  20. .
    Info
    titleNote
    The parameter does not affect the MJPEG video format, as all frames in it are key frames
  21. .
  22. To position the found fragment in the center of the screen, enable
  23. the 
  24. the Scroll selected search result to the center parameter (3). This setting is common to all Web-Client users in a particular browser.
  25. Set the default interval for the TimeSlice search (4,

  26. see 
  27. see Types of archive search in the Web-Client). This setting is common to all Web-Client users in a particular browser.

  28. By default, the Cameras panel
  29. does not
  30. doesn't close after you select a device. To minimize the panel, disable
  31. the 
  32. the Manually open and close
  33. parameter 
  34. parameter (5). This setting is common to all Web-Client users in a particular browser.
  35. When
  36. By default, when you select a camera, it opens full screen. To open the layout containing the selected camera when you select a camera
  37. in
  38. on the Cameras panel,
  39. a layout containing
  40. enable the Open selected camera
  41. will open
  42. on layout parameter (6). If
  43. there are several such layouts, then the one with fewer cells is selected. To expand the video camera to full screen, disable the Open selected camera on layout parameter (6). This
  44. the selected camera is on the current layout, it becomes active. If the selected camera is on other layouts, the first layout that has a camera is selected. This setting is common to all Web-Client users in a particular browser.
  45. By default, the Web-Client displays only the
  46. enabled
  47. active cameras. If you want the Web-Client to display all cameras, disable
  48. the 
  49. the Show only live cameras
  50. parameter 
  51. parameter (7). This setting is common to all Web-Client users in a particular browser.
  52. By default, the Web-Client displays the cameras IDs. In order to disable the cameras IDs display, disable the Show device IDs parameter (8). This setting is common to all Web-Client users in a particular browser.
  53. By default, the Web-Client cameras and bookmarks display the
  54. Server
  55. server time. If you want the Web-Client cameras and bookmarks to display the client time, disable
  56. the 
  57. the Use server timezone
  58. parameter 
  59. parameter (9). This setting is common to all Web-Client users in a particular browser.
  60. By default, the Web-Client displays time in the 24-hour format and date in the DD-MM-YYYY format. If you want the time to be displayed in the 12-hour
  61. format, disable the 
  62. format and the date to be displayed in the MM-DD-YYYY format, enable the Use 12 hour time format
  63. parameter 
  64. parameter (10). This setting is common to all Web-Client users in a particular browser.
  65. If you can view the interactive map in the Web-Client, the names of all camera markers added to the map are displayed by default. To disable the display of marker names on the interactive map, disable the Show marker names parameter (11). This setting is common to all Web-Client users in a particular browser.
  66. By default, in the Web-Client, the size of the surveillance windows in the layout is proportional to the resolution of the video image. To ensure that the video image takes up the entire space of the surveillance window, disable the Keep aspect ratio (12) parameter. As a result, the video image will be stretched over the entire surveillance window. This setting is common to all Web-Client users in a particular browser.
  67. Click the Image Added button.

Configuring the Web-Client is complete.

Changing the user password in the Web-Client

To change the user password in the Web-Client, do the following:

  1. Click the Image Added button in the top right corner and then click the Image Added button.
  2. Click the Image Removed button
  3. Image Added
  4. In the window that opens, enter the new password and confirm the new password.
    Image Added
  5. Click the Change button.

Changing the user password in the Web-Client is complete.