The settings panel of the SIP-operator object is shown in the pictures figures below.
Table describes the setting parameters of the SIP-operator system object.
№ | Parameter | Method for setting the parameter value | DescriptionParameter description | Presented asRepresentation | Default value | Range of valuesValue range |
1 | The Number fieldAutomatically | Enter the value into the field | Sets the identification number for callsSequence of numbersof the operator to which you can call | Numbers, letters, periods, hyphen, dash and underscore | - | >=0 |
2 | The Bind operator to user rights checkbox | Set the Is set with a checkbox | Enables binding of a SIP-operator to Intellect user rights. Activates the User drop-down list. Note. It is used when the User rights are selected by default on the operator's SIP-panel. | Yes - binding Set—binding of a SIP-operator to Intellect user rights is enabledNo - binding Clear—binding of a SIP-operator to Intellect user rights is disabled | ||
3 | The User drop-down list | Select the value from Is selected in the list | Sets the user under which it is necessary to register in Intellect. | Name of the User objects registered in the system. | Depends on the number of the User objects in the system. | |
4 | The Device priority drop-down list | Select the value from Is selected in the list | Sets the priority of a call from this operator in the incoming calls window of the SIP-panel. | Sequence of numbers | No | 0 – 100–10 The lower the number, the higher the priority and, accordingly, the higher the display in the list. If the field is left blank, then the priority is considered to be minimal. Calls from operators with the same priority will be sorted by the time of the call. |
The Server connection tab (only for the SIP-client terminal type).
Table describes the setting parameters of the Server connection tab.
№ | Parameter | Method for setting the parameter value | DescriptionParameter description | Presented asRepresentation | Default value | Range of valuesValue range |
1 | The Login field | Enter the value in into the field | Sets the username login for connecting to the SIP-server | Latin, Cyrillic letters and service characters | - | A line representing containing a sequence of any symbols characters (letters, numbersdigits, service symbolscharacters) |
2 | The Password field | Enter the value in into the field | Sets the password for connecting to the SIP-server | Latin, Cyrillic letters and service characters | - | A line representing containing a sequence of any symbols characters (letters, numbersdigits, service symbols)characters |
The Address book tab.
Table describes the setting parameters of the Address book tab.
№ | Parameter | Method for setting the parameter value | DescriptionParameter description | Presented asRepresentation | Default value | Range of valuesValue range |
1 | The Address books table | Select the value Is selected in the column | Sets the list of address books, the numbers of which should will be available for this SIP-operator | - | - | - |
The Number column | Select the value from Is selected in the list | Selecting Selects the address book identifier | Identifiers of the Address book objects registered in the system | - | Depends on the number of of the Address book objects in the system | |
The Name column | Select the value from Is selected in the list | Selecting Selects the name of the address book in Intellect | Names of the Address book objects registered in the system | - | Depends on the number of of the Address book objects in the system | |
2 | The All button | Click the button | Adds all existing address books to the table | - | - | - |
3 | The Range button | Click the button | Opens the Add address books window to add multiple address books | - | - | - |
...