Go to documentation repository
The settings panel of the SIP-panel object interface object is shown in the figures belowfigure.
The Basic settings tab
Table The table describes the setting parameters of the SIP-panel interface object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* field | Automatically | Displays the identification number of the SIP-panel object in the system | Digits, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the SIP-panel objects in the system |
2 | The Name* | Enter the value in the field | Sets the name of the SIP-panel object in the system | Latin alphabet, Cyrillic, digits, and service characters | SIP-panel | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | The Disable | Set the checkbox | Disables the SIP-panel object in the system | Boolean type | Clear | Set—the SIP-panel object is disabled and isn't used Clear—the SIP-panel object is enabled and used |
4 | The Display | Select the value from the list | Sets the Display parent object for the given SIP-panel object | Names of the Display objects registered in the system | Name of the Display | Depends on the number of the Display objects in the system |
The Position group |
5 | The X field | Enter the value |
in the field | Sets the X coordinate in the horizontal axis for the upper left corner of the |
SIP- |
panel window | % of the screen width |
0 | From 0 to M*100, where M is the number of the installed monitors |
The Y field | Enter the value |
in the field | Sets the Y coordinate in the vertical axis for the upper left corner of the |
SIP-panel |
window | % of the screen height |
45 | From 0 to M*100, where M is the number of the installed monitors |
2
The W field | Enter the value |
in the field | Sets the width of the SIP-panel |
window | % of the screen width |
15 | From 0 to M*100, where M is the number of the installed monitors |
The H field | Enter the value |
in the field | Sets the height of the SIP-panel |
window | % of the screen width |
50 | From 0 to M*100, where M is the number of the installed monitors |
The button | Click the button | Opens |
the window for changing the |
position and size of the SIP-panel window |
NA |
NA |
NA |
The Monitor drop-down list | Select the value from the list |
Determines the number of the monitor in the system for which the coordinates are specified | Numbers of the monitors in OS | 1 | From 1 to 16 | |||
The |
...
Operator interface settings |
...
group |
Table describes the parameters of the Basic settings tab.
6 | The Terminal drop-down list |
Select the value from the list | Sets the SIP-terminal object, which SIP |
devices use the SIP-panel |
Names of |
the SIP-panel objects registered in the system |
NA | Depends on the number of the SIP-terminal objects in the system |
The Monitor drop-down list | Select the value from the list | Sets |
the Monitor object corresponding to the |
video surveillance monitor to which the |
cameras associated with the corresponding SIP |
devices are added |
Names of |
the Monitor objects registered in the system |
NA | Depends on the number of the Monitor objects in the system |
The Advanced settings settings tab.
Table
The table describes the parameters of the Advanced settings tab.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
The Interface behavior group | ||||||
1 | The Display only when calling checkbox | Set the checkbox | Displays the SIP-panel only when calling | Boolean type | Clear | Set— |
the SIP- |
panel is only displayed when calling Clear— |
the SIP- |
panel is always displayed |
The New calls to the end checkbox | Set the checkbox | Enables adding new calls to the end of the list | Boolean type | Clear | Set—new calls are added to the end of the list Clear—new calls are added to the top of the list |
The Disable keypress sound checkbox | Set the checkbox | Disables keypress sound on the SIP-panel | Boolean type | Clear | Set—keypress sound is disabled Clear—keypress sound is enabled |
The Maximize screen on call checkbox | Set the checkbox | Enables automatic display switching on call | Boolean type | Clear | Set—when a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen to which the SIP-panel is added is displayed automatically Clear—when a call is made to the SIP-terminal that corresponds to the SIP-panel, |
screens aren't switched automatically | ||
The Calls to unknown users checkbox | Set the checkbox | Enables the option to call the unknown users. Note. Unknown user is a number that is present in the SIP-terminal |
but not in the address book of the current SIP-operator | Boolean type | Set | Set—calls to unknown users are allowed Clear—calls to unknown users are |
forbidden | ||
The Switch to incoming checkbox | Set the checkbox | Automatically switches to |
the SIP-panel tab with the incoming calls, which occurs |
during incoming calls or |
calls on hold | Boolean type | Set | Set—automatic switch to the tab with incoming calls is enabled |
Clear—automatic switch to the tab with incoming calls is disabled | ||||||
The Interface elements group |
2 | The Dial pad checkbox | Set the checkbox | Displays the dial pad in the interface | Boolean type | Set | Set—the dial pad is displayed Clear—the dial pad is hidden |
The Subject checkbox | Set the checkbox | Displays the tab names in the interface. When disabled, only the Call tab |
is displayed without displaying the name | Boolean type | Set | Set—the tab names are displayed Clear—only the Call tab is displayed without displaying the name | ||
The Archive checkbox | Set the checkbox | Displays the Archive tab in the interface | Boolean type | Set | Set—the Archive tab is displayed Clear—the Archive tab is hidden |
The Call control buttons checkbox | Set the checkbox | Displays the buttons at the bottom of the panel to control a call | Boolean type | Set | Set—call control buttons are displayed Clear—call control buttons are hidden |
The Operator settings tab
...
Table The table describes the parameters of the Operator settings tab.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1
The Operators table |
1 | The Number drop-down list |
Select the value from the list | Selects |
the SIP-operator identifier | Identifiers of |
the SIP-operator objects registered in the system |
NA | Depends on the number of the SIP-operator objects in the system | |
The Subscriber drop-down list | Select the value from the list | Selects |
the SIP-operator number | Numbers of |
the SIP-operator objects registered in the system |
NA | Depends on the number of the SIP-operator objects in the system | |
The Name drop-down list | Select the value from the list | Selects |
the SIP- |
operator name in Axxon PSIM | Names of |
the SIP-operator objects registered in the system |
NA | Depends on the number of the SIP-operator objects in the system | |||||
Out of the group | ||||||
2 |
The Range button | Click the button |
Opens the Add operators window to add multiple SIP operators | NA | NA | NA |
3 | The All button |
Click the button |
Adds all existing SIP operators to the table | NA | NA | NA |
4 | The Default drop-down list | Select the value from the list | Sets the default SIP |
operator |
NA | Select on start |
|
|
|
|
|
|
|
|
|
|
|
|
*Name of the element isn't displayed in the settings panel of the given object