Note |
---|
|
The Microphone object must be enabled (see The Microphone Object). |
To configure the Audio Analytics Detection classification IV, do the following:
Submit to the technical support the MAC address of the Server server where the detection tool detector will be used.
Note |
---|
|
The detection tool detector will not work on the Server server with a different MAC address. |
- Copy the license received from the technical support into the C:\Program Files\Common Files\AxxonSoft\DetectorPack\LicenseFile_AudioIV.txt file.
- Restart the Server server (see Shutting down a Server Stopping the server, Starting a Serverthe server).
On the Detection Tools tab Detectors tab, below the required camera, click Create… → Category: Production Safety → Audio Analytics Detection classification IV.
By default, the detection tool detector is enabled and set to recognize and detect all sounds specified in the settingsthe following types of sounds:
- the sound of aggressive behavior,
- the sound of a gunshot,
- the sound of a smoke alarm,
- the sound of a child crying,
- the sound of breaking glass,
- the sound of a siren,
- the sound of a dog barking.
If necessary, you can change the detection tool detector parameters. The list of parameters is given in the table:
Note |
---|
|
Recommendation for the sound detection threshold parameters: start with a value of 0.99 and gradually lower it if the detector misses target events, or increase it if there are too many false events. - A high value (close to 1): lower sensitivity, fewer false events, but a higher risk of missing an event.
- A low value (close to 0.01): high sensitivity, better detection, but more false events.
|
Parameter | Value | Description |
---|
Other |
Enable | Yes | By default, the |
detection tool detector is enabled. To disable, select the No value |
No |
Name | Audio |
Analytics Detection classification IV | Enter the |
detection tool detector name or leave the default name |
Aggression detection | Yes | By default, the aggression detection is enabled. To disable, select the No value |
No |
Aggression detection threshold | 0.99 | Specify the sensitivity threshold |
value at which the sound is recognized as aggression. The value must be in the range [0.01, 1] |
Baby cry detection | Yes | By default, the baby cry detection is enabled. To disable, select the No value |
No |
Baby cry detection threshold | 0.99 | Specify the sensitivity threshold |
value at which the sound is recognized as a baby cry. The value must be in the range [0.01, 1] |
Dog bark detection | Yes | By default, the dog bark detection is enabled. To disable, select the No value |
No |
Dog bark detection threshold | 0.99 | Specify the sensitivity threshold |
value at which the sound is recognized as a dog bark. The value must be in the range [0.01, 1] |
Glass break detection | Yes | By default, the glass break detection is enabled. To disable, select the No value |
No |
Glass break detection threshold | 0.99 | Specify the sensitivity threshold |
value at which the sound is recognized as glass |
breakbreaking. The value must be in the range [0.01, 1] |
Gunshot detection | Yes | By default, the gunshot detection is enabled. To disable, select the No value |
No |
Gunshot detection threshold | 0.99 | Specify the sensitivity threshold |
value at which the sound is recognized as a gunshot. The value must be in the range [0.01, 1] |
Siren detection | Yes | By default, the siren detection is enabled. To disable, select the No value |
No |
Siren detection threshold | 0.99 | Specify the sensitivity threshold |
value at which the sound is recognized as a siren. The value must be in the range [0.01, 1] |
Smoke alarm detection | Yes | By default, the smoke alarm detection is enabled. To disable, select the No value |
No |
Smoke alarm detection threshold | 0.99 | Specify the sensitivity threshold |
value at which the sound is recognized as a smoke alarm. The value must be in the range [0.01, 1] |
Type | Audio |
Analytics Detection classification IV | Name of the |
detection tool To save the changes to the detection tool detector parameters, click the Apply
Image Added button. To cancel the changes to the parameters, click the Cancel
Image Added button.
Configuration of the Audio Analytics Detection classification IV is complete.
If necessary, you can search the archive for events that were generated by the detection tooldetector. You can search for all types of sounds or for a specific type of sound (see Events search).