The Macro object is designed used to support the automatic execution of a pre-defined sequence of commands upon occurrence of certain events, registered by the Intellect™ system Intellect.

The settings panel of the Macro object is shown in the figure.

Image Modified

The table Table describes the setting parameters of the settings corresponding to the elements of the settings panel of the Macro object.

entering Symbols used click hot clicking .NoSome .The dropdown list in dropdown . appearance . appearances - .

Parameter

Method for

setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Macro command object in the digital video surveillance system.Sequence of numbers

Numbers, letters, periods, hyphen, dash and underscore

-

Depends on the number of the Macro command objects in the digital distributed video surveillance system .with distributed architecture

2

Name*

Enter the value in into the field

Defines Sets the Macro command object  object name.

Latin, Cyrillic and service characters

Macro

A line containing a sequence of any symbols characters (letters, digits, service characters apart from except > and < symbolscharacters), case-insensitive.

Number of symbols – from characters—from 1 to 60.

3

Disable

Is identified by the check mark

Set the checkbox

Sets the state Defines the Macro command object status (enabled or disabled) .of the Macro object 

Boolean type

Not available

Clear

SetYesthe Macro command object is disabled and is not in useNo – the macro command isn't used

Clearthe Macro object is enabled and is in use.used

The Settings Group group

4

State

Enter the value in into the field

Defines Sets the message displayed in the information board of the main menu of the Intellect system, when the given macro command is running.

Latin, Cyrillic and service characters

Not defined

1. Standard no message will be displayed in the information board of the main menu of the Intellect system.

2. A line containing a sequence of any symbols characters (letters, digits, service characters), case-insensitive.

Number of symbols – charactersfrom 1 to 60.

5

Local

Is identified by the check mark

Set the checkbox

Sets Defines the computers, which will execute the given macro command (all computers of the digital distributed video surveillance system with distributed architecture or only the given computer).

Note. This checkbox does not apply to Hide hide and Show show reactions of any Display. Regardless of the checkbox, wen when called from the Server/RAW, they the reactions are executed on the Server/RAW and all connected Clients; when called on the Client, they the reactions are executed only on the client.Client

Boolean type

Not available

Clear

Set—the macro will be executed only on the given computer

Clear—Yesthe given macro command will be executed by on all computers of the digital distributed video surveillance system .No – the macro command will be executed only by the given computer.with distributed architecture

6

Hidden

Is identified by the check mark

Set the checkbox

DeterminesDefines, whether or not the name of this macro command will be displayed in the main control panel of the Intellect system to be launched started manually.

Boolean type

Not available

Clear

Set— the name of the macro will not Yes – no macro command will be displayed in the main control panel of the Intellect system.No

Clearthe name of the macro command will be displayed in the main control panel of the Intellect system.

The Events Subgroup subgroup

7

Type

Is selected Select the value from the list

Defines Sets the type of objects in the digital distributed video surveillance system with distributed architecture, in which registration of events initiates macro command execution.the event registration triggers a macro

Types of objects registered in the system.

Empty field-

Depends on the total number of the types of objects created in the digital distributed video surveillance system .with distributed architecture

8

Number

Is selected Select the value from the list

Defines Sets the identification number of the object in the digital distributed video surveillance system with distributed architecture, in which registration of events initiates macro command execution.the event registration triggers a macro

Sequence of numbers

Empty field-

Depends on the total number of the given types of objects objects of the specified type created in the digital distributed video surveillance system .with distributed architecture

9

Name

Automatically

Displays the name of the selected object in the digital distributed video surveillance system .with distributed architecture

Name Names of the  the objects of the same specified type registered in the system

Empty field-

A line containing a sequence of any symbols characters (letters, digits, service characters), case-insensitive.

Number of symbols – charactersfrom 1 to 60.

10

Event

Is selected Select the value from the list

Defines Sets the event , which, when registered that triggers a macro for the pre-defined object, initiated macro command execution.specified object

Names of the events available Events registered for the given type of objects.

Empty field-

List of events is created separately individually for each type of object.

The Parameters Subgroup subgroup

NOTENote. The given subgroup is not active for some all types of objects.

11

Name

Automatically

Defines an additional Sets the name of the additional parameter for the selected type of object in the Events subgroup.

Latin , and service characters and , digits.

Not defined

A line containing a sequence of any symbols characters (letters, digits, service characters), case-insensitive.

Number of symbols – from characters—from 1 to 60.

12

Value

Enter the value in into the field

Defines Sets the value for the parameter of in the Name column.

Latin , and service characters and , digits.

Empty field

A line containing a sequence of any symbols characters (letters, digits, service characters), case-insensitive.

Number of symbols – charactersfrom 1 to 250.

The Action Subgroup subgroup

13

Type

Is selected Select the value from the list

Defines Sets the type of objects in the digital distributed video surveillance system with distributed architecture, to which the command is forwarded, when the conditions defined set in the Events subgroup for to trigger a macro command initiation are met.

Types Names of the types of objects registered in the system.

Empty field-

Depends on the total number of the types of objects created in the digital distributed video surveillance system .with distributed architecture

14

Number

Is selected Select the value from the list

Defines Sets the identification number of the object in the digital distributed video surveillance system with distributed architecture, to which the command is forwarded, when the conditions defined set in the Events subgroup for to trigger a macro command initiation are met.

Sequence of numbers

Empty field-

Depends on the total number of the given types of objects created objects of the specified type in the digital distributed video surveillance system with distributed architecture.

If the field is left blank, the reaction will be performed for all objects of the selected type.

If you enter the# symbol # in the field, the identifier of the object from which the event was received will be substituted into the reaction. The object types in the Events and Actions tables may differ. When the macro is run manually from the main control panel, the # symbol is treated as if the field was blank, i.e. the macro is executed for all objects of the selected type.
Example of using the # symbol: disarm the camera if the “Detach” event is was received from it.

15

Name

Automatically

Displays the name of the selected object in the digital distributed video surveillance system .with distributed architecture

Name Names of the  the objects of the same selected type registered in the system

Empty field-

A line containing a sequence of any symbols characters (letters, digits, service characters), case-insensitive.

Number of symbols – charactersfrom 1 to 60.

16

Action

Is selected Select the value from the list

Defines Sets the action, which the given device performs, when the conditions for to trigger the given macro command initiation are met.

Actions, registered by Names of the actions, available in the system for the objects of the given specified type of objects.

Empty field-

List of events is created separately individually for each type of object.

The Parameters Subgroup subgroup

NOTENote. The given subgroup is not active for all types of objects.

17

Name

Automatically

Defines an Sets the name of the additional parameter for the selected type of object in the Actions subgroup.

Latin , and service characters and , digits.

Not defined

A line containing a sequence of any symbols characters (letters, digits, service characters), case-insensitive.

Number of symbols – from characters—from 1 to 60.

18

Value

Enter the value in into the field

Defines Sets the value for the parameter of in the Name column.

Latin , and service characters and , digits.

Empty field-

A line containing a sequence of any symbols characters (letters, digits, service characters), case-insensitive.

Number of symbols – charactersfrom 1 to 250.

Outside the groups

19

Response sending delay (sec.)

Enter the value in into the field

Sets the time period (in seconds) that must pass after the events specified in the Events column occur and before executing the reactions specified in the Actions column.


Note.Iftheeventsreoccurbeforethespecifiedtimeperiodexpires, thereactionexecutionwaitperiodis will be prolonged, i.e. reactions will be executed only once when events do not reoccur over the specified period.

Integer numberSequence of numbers

-

>0

20Fast call

Left-click in the field and

press the required key combination

Sets a keyboard shortcut for a macro.

Note. If the same combination of

keys is set for several macros, when

pressing a key combination, all of these macros will run

Key combinations-Individual keys of the main or numeric keyboard, as well as these keys in combination with Shift, Ctrl and Alt
21Icon typeSelect the value from the list

Sets a set of icons for displaying a macro on the map. By default, an empty value is set for all macros which corresponds to the "Macro 1" icon.

Note. Changing the icon

type will take effect after restarting the map interface. To restart the interface, restart Intellect or log in once again under the corresponding Operator account

Available icon

types on the map

-Macro 1Macro 7, empty value

*The name Name of the element is not isn't displayed in the User’s rights settings panel of the given object.