This page lists integration modules with limited functionality implemented for specific projects. These modules are present in the ACFA - Intellect installer and are supported, but may not contain all the necessary functions. Please contact ITV | AxxonSoft technical support to clarify which features are supported.

Common name

Integrated hardware (name of devices)

Functionality/Restrictions

Name in price

-

list

Information on manufacturer

Way of integration

Hardware connection interface

ACFA
-
Intellect version
Anson DBAndy ME12Monitoring*INTELLECT Access Control Service (Anson), per system

INDI

andi-bg.com
low-level protocolEthernet-
AritechFP2000 seriesMonitoring, control/Multiple panels on one COM port are not supported (i.e. via converters like UN2011). Events from the panel are supported partially.INTELLECT Alarm Service (Aritech), per panel
Aritech 

Aritech
www.aritech.pro

low-level protocolRS-2325.3
Impro

Impro (ECII) Ethernet Controller

Impro (iTRT) Intelligent Twin Reader Terminal

Impro (iTT) Intelligent Twin Antenna Terminal

Impro (MDTA) Multi-discipline Time Attendance
Terminal

Impro I16 16 Channel Input Terminal

Impro O16 16 Channel Output Terminal

Hirsch Velocity
M8N, M2N, M16Monitoring*INTELLECT Access Control
and Fire Alarm
Service (
Impro
HIRSCH Velocity), per
terminal
reader
Impro Technologies

Identiv

http

https://www.

impro

identiv.

net

com/

SOFT-SOFTEthernet
, RS485
5.
3
4
Hirsch Velocity
M8N, M2N, M16

Rakinda

RD007Monitoring and control of entrances
Monitoring*
INTELLECT Access Control Service (
HIRSCH Velocity
Rakinda), per reader

Identiv

https

Shenzhen Rakinda Technology Co., Ltd
5F Building A2 , Lee Lang Software Park, Bu Lan Road 31, Longgang District, Shenzhen City, Guangdong, China
Phone: +86 755 8323 3013
Email: wyp@rakinda.com
http://www.

identiv

rakinda.com

/

SOFT-SOFT
SDKEthernet
5
6.
4
8

STX-1000

STX-1000Monitoring, control/ Only position sensor functionality is integrated.

GS Software

ul. Półłanki 80 lok 402

HundureHundure IM1000UIntegration is made for a specific project. The device is designed to encode Mifare cards. In the integration module, the code written to the card is generated according to a certain non-customizable algorithm.Licensed as control reader

HUNDURE
7F., No.10, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan
Phone+ 886 2 2999-2240, + 886 2 2999-2395
Email: overseas@hundure.com
http://www.hundure.com/

30-740 Kraków, Poland

Tel.: (+48) 12 444 69 36

www.gs-software.pl

Low-level protocolRS-232
, RS-485
6.8
ControlIDiDSecureOnly user import from iDSecure to Intellect databaseINTELLECT Database Import Service (Control ID)

ControlID
https://www.controlid.com.br

SOFT-SOFTEthernet6.9

Bosch APE

Only entrances connectable to Bosch Access Professional Edition (APE) softwareOnly monitoring and control of entrances

INTELLECT Access Control Service (Bosch APE Server), per system

INTELLECT Access Control Service (Bosch APE Entrance), per entrance

Bosch Sicherheitssysteme GmbH
https://www.boschsecurity.com/

SOFT-SOFT-6.9
6.8


Info