Go to documentation repository
In Axxon PSIM software, you can use different streams from the camera for displaying video on the video surveillance monitor, archiving, and video analytics. For example, this option lets you display a low-quality video on the monitor while recording a high-quality video to the archive, which reduces the load on the client.
...
Set the checkbox in the Default column next to the stream number that you need to use in the following cases:
To send to remote clients, including the Videogate, that can record this video stream.
Info | ||
---|---|---|
| ||
If a specific video stream is requested via Videogate, then the requested stream, not the Default one, is transmitted. |
When a video request doesn't contain a specified video stream.
Info | ||
---|---|---|
| ||
You can use this stream, for example, to display video on the video surveillance monitor if a default stream has been selected for the camera or for displaying video on the video surveillance monitor of the web server. |
Set the checkbox in the Video analytics column next to the stream number that you need to use for the face recognition server, the main motion detector, zone detectors, tracking detectors, and face detectors (if an external recognizer isn't used).
Set the checkbox in the Archive column next to the stream number that you need to record to the archive, not upon alarm, for example, during continuous recording.
Set the checkbox in the Archive (alarms) column next to the stream number that you need to record to the archive upon alarm.
You can use this stream for backup archiving.
Info | ||
---|---|---|
| ||
If you select different streams for recording to the archive upon alarms and continuous recording where when recording is performed nonstop and detectors are enabled, then the recording of the current archive fragment stops upon alarm in the continuous recording stream, and recording of a new fragment starts in the alarm recording stream. When the alarm ends and after post-alarm recording, the continuous recording with the corresponding stream resumes. If you select the same stream for recording to the archive upon alarms and continuous recording, then recording of the current fragment doesn't stop upon alarm. |
Info | ||
---|---|---|
| ||
If you configure pre-alarm recording, then when selecting different streams for recording to the archive upon alarms and continuous recording, some archive recordings overlay as the following video fragment starts earlier than the previous one ends. |
In the Codec group, specify the video stream parameters (see The Settings settings panel of the Camera object): codec, key frame rate, and video quality.
Note | ||
---|---|---|
| ||
The following video streams are available for Axis cameras: 1. Receiving H264/MJPEG/MPEG4 video. You can specify video stream settings using the Axxon PSIM software package facilities. Specify these settings in the the Video stream 1 tab. |
...