The Web-server object is used for video surveillance via the Internet a web browser and the TCP/IP communication environment.The  The settings panel of the Web-server object is shown in the figureand its description are given below.

The Basic settings tab.

Image Removed

The List of cameras tab.

Image Removed

Table describes the setting parameters corresponding to the elements of the settings panel of the Web-server object.

Image Added

Parameter

Method

for

of setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Web

-

server object in the

digital

video surveillance system with

the

distributed architecture

Sequence of numbers

-

From 1 and above.

Depends on the number of the Web

-

server objects in the

digital

video surveillance system with

the

distributed architecture

From 1 to 2147483647

2

The Name*
field

Enter the value

into

in the field

Sets the name of the Web

-

server object in the

digital

video surveillance system with

the

distributed architecture

Latin alphabet, Cyrillic, digits and service characters

Web-server

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Sets the state (enabled or disabled) of the Web-server

Disables the Web server object in the

digital

video surveillance system with

the

distributed architecture

Boolean type

Clear

Setthe Web

-

server object is disabled and isn't used

Clearthe Web

-

server object is enabled and used

4

The Computer
drop-down list

Select the value from the list

Sets the Computer parent object of the

digital

system with

the

distributed architecture

,

to which the given Web

-

server object belongs

Name

Names of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the

digital

video surveillance system with

the

distributed architecture

The HTTP-server group

5



The Port number
field

Enter the value

into the

in the field

Sets the number of the port used by the HTTP

-

server (used for video surveillance via

the Web-

a web browser, including

via

through the

Internet

internet)

Sequence of numbers

80

Any valid unused port numbers.

The number of ports is determined by the system administrator

.

6

The Number of connections
field

Enter the value

into

in the field

Sets the maximum possible number of connections to the

Server

server via the Web

-

server module.

Each request to view the video signal from each camera and each request to control all PTZ devices

regadless

, regardless of their number, is considered as a connection

pcs
Sequence of numbers

100

Any integer.

If you specify the 0 value

is specified on the Video Monitor

in the video surveillance monitor of the Web-server module, video signals

won

aren't

be Use HTTPS protocol

displayed

Not in a group

7

Default user

Select the value from the list

Sets the user with rights and authority to conduct the video surveillance from the Remote workstation using the Web-server module

Names of the users registered in the system and added to the rights

Not defined

Depends on the number of the users registered in Axxon PSIM

8

ECHD translation

Set the checkbox

Enables to use the http requests used for integration with ECHD

Boolean type

Clear

Setrequests used for integration with ECHD are run for the Camera objects on the basis of which the ECHD channel objects are created

Clearrequests used for integration with ECHD are not run

9

RTSP-server

Select the value from the list

Sets the RTSP server to process the ECHD requests

Names of the RTSP-server objects registered in the system

Not defined

Depends on the number of the RTSP-server objects in the digital video surveillance system with the distributed architecture

10Use NAT addressSet the checkboxEnables the router address substitution in the ECHD requestsBoolean typeClearSet—when requesting the URL of streams via the HTTP API, the IP address of the router specified in the settings panel of the RTSP-Server object is substituted in the response to the request
Clear—when requesting the URL of streams via the HTTP API, the IP address of the Server in its local network is returned in response to the request

The HTTPS-server group

11

The Parallel exports
field

Enter the value in the field

Determines the maximum allowed number of archive files to be uploaded simultaneously

Sequence of numbers

2

From 1 and above.

If you leave the field blank, the lowest possible value is used

The HTTPS-server group

6




The Use HTTPS protocol
checkbox


Set the checkbox

Enables the HTTPS protocol when

transmitting

you transmit data via the Web

-

servermodule

Boolean type

Clear

Set—

Setthe HTTPS protocol is used

Clear—

Clearthe HTTPS protocol isn't used

12

The Key

Enter key

field

Enter the value

into

in the field

Key

Sets the path to the folder of the key for data transmission via the HTTPS protocol

Latin alphabet, Cyrillic and service characters

C:\Program Files (x86)\Axxon PSIM\Modules\SSL\ssl_internal.key

Depends on the location of data encryption key when

transmitting

you transmit data via the HTTPS protocol

13

The Certificate

Certificate

field

Enter the value

into the

in the field

Certificate

Sets the path to the folder of the certificate for data transmission via the HTTPS protocol

Latin alphabet, Cyrillic, and service characters

C:\Program Files (x86)\Axxon PSIM\Modules\SSL\ssl_internal.cert

Depends on the location of certificate file when

transmitting

you transmit data via the HTTPS protocol

14

The Port number
field

Enter the value

into

in the field

Sets the number of the port used for the HTTPS

-

server (used for video surveillance in

the

a web browser and

in

via the

Internet

internet)

Sequence of numbers

443

Any available unused port numbers.

The number of ports is

specified

determined by the system administrator

Out of the group

7

The Default user
drop-down list

Select the value from the list

Sets the user with permissions and authority to conduct the video surveillance from the Remote workstation using the Web server module

Names of the users registered in the system and added to the permissions

NA

Depends on the number of users registered in Axxon PSIM

8

The ECHD translation
checkbox

Set the checkbox

Enables the use of the HTTP requests used for integration with ECHD

Boolean type

Clear

Setrequests used for integration with ECHD are executed for the Camera objects on the basis of which the ECHD channel objects are created

Clearrequests used for integration with ECHD aren't executed

9The Use NAT address
checkbox
Set the checkboxEnables the router address substitution in the ECHD requestsBoolean typeClearSet—when you request the URL streams via the HTTP API, the IP address of the router specified in the settings panel of the RTSP Server object is substituted in the response to the request

Clear—when you request the URL streams via the HTTP API, the IP address of the server in its local network is returned in response to the request

The List of cameras tab

Image Added

15

Range

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

10

The Range
button

16

Clear


Click the button

Opens the

dialog box for complex selection of video cameras

-

-

-

window for bulk addition of cameras (see Bulk selecting and configuring cameras for the Web-server)

NANANA

11

The Clear
button


Click the button

Clears the list of the added

video

cameras

-
NA
-
NA
-
NA
17

12

The Add all
button

Click the button

Adds to the list of

video

cameras all Camera objects created in the system

-
NA
-
NA
-
NA
18

13

The Number
drop-down list

Select the value from the list

Sets the number of the camera the video from which is transmitted to the remote workstation

using

via the Web

-

server module

Identifiers of the Camera objects registered in the system

Not defined
NA

Depends on the number of

the video

cameras in the

digital

video surveillance system with

the Camera

distributed architecture

19

The Camera
drop-down list


Select the value from the list

Sets the name of the camera the video from which is transmitted to the remote workstation

using

via the Web

-

server module

Names of the Camera objects registered in the system

Not defined
NA

Depends on the number of

the

cameras in the

digital

video surveillance system with

the

distributed architecture

20

The Video stream
drop-down list

Select the value from the list

Sets the number of the video stream used for displaying in the interface of the Web

-

server

interface

 module

Numbers of video streams enabled on the camera and the By default value

By default

Depends on the number of the camera enabled streams

on the camera

21

The Live video
drop-down list

Select the value from the list

Sets the source of live video that is displayed in the interface of the Web

-

server

interface

 module

Available means to get live video

Server

server

Serverlive video is received from the

Server

 server to which the camera is connected.

Videogatelive video is received

from the Videogate

through the videogate.

Note. If a camera

is not

isn't configured to transmit video through the

Videogate

videogate,

then Archive

this item is unavailable in the list

22

The Archive
drop-down list


Select the value from the list

Sets the source of the archive video that is displayed in the interface of the Web

-

server

interface

 module

Available means to get archive video

Server

server

  • Disabled—archive video isn't transmitted;
  • Serverarchive video is received from the
Server to
  •  server to which the camera is connected;
  • Backup archivearchive video is received from the backup archive;
  • Videogatearchive video is received from the
Videogate
  • videogate archive. If a camera
is not
  • isn't configured to transmit video through the
Videogate
  • videogate,
then

23

Microphone
  • this item is unavailable in the list
.

Backup archivearchive video is received from the Backup archive 

The Microphone
drop-down list


Select the value from the list

Sets the name of the microphone associated with the camera, the

sound

audio from which

will be

is transmitted through the Web

-

server module

Names of the Microphone objects registered in the system

Not defined
NA

Depends on the number of the Microphone objects in the

digital

video surveillance system with

the Speaker

distributed architecture

24

The Speaker
drop-down list


Select the value from the list

Sets the name of the speaker associated with the camera, which

will be

is used to

playback

play back the

sound

audio received from the client

Names of the Speaker objects registered in the system

Not defined
NA

Depends on the number of the Speaker objects in the

digital

video surveillance system with

the Compression

distributed architecture

25

The Compression
drop-down list


Select the value from the list

Sets the compression level of the video signal transmitted to the remote workstations using the Web

-

server module. Increasing the level of compression leads to the deterioration of the video signal quality

Reference compression levels

Not defined
NA

Not defined, from 1

to 5.

Value 1

The 1 value corresponds to the minimum compression level, the 5to the maximum compression level.

If the compression level

is not

26

Control

isn't specified, the video signal is transmitted with the same compression level as set for recording and transmitting

video

videos to the network

The Control
drop-down list


Select the value from the list

Sets

Enables the camera control (arm/disarm, PTZ, recording to the archive) according to the user

rights

permissions

Boolean type

Enabled

Enabledcamera control according to the user

rights

permissions is enabled

Disabledcamera control is disabled regardless of the user

rights

permissions

27
14The PTZ control
drop-down list
Select the value from the list
Set
Sets the
prioritiy for
priority of the PTZ control
in
 during video surveillance using
the
a web browserNames of the PTZ control prioritiesLow priority
  • Forbiddenoption of the PTZ control
in
  • with a web browser
is disabled
  • at video surveillance;
  • Low prioritylow priority of control;
  • Medium prioritymedium priority of control;
  • High priorityhigh priority of control

The RTSP settings tab

Image Added

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

15

The RTSP server
list

Automatically

Displays the list of the RTSP Server objects registered in the system to process ECHD requests

Name of the RTSP Server objects

NA

List of the RTSP Server objects registered in the system to process ECHD requests

The RTSP server
checkbox

Set the checkbox

Selects from the list (one or several) the RTSP Server objects registered in the system to process ECHD requests

Boolean type

Clear

Set—RTSP server is used to process ECHD requests

Clear—RTSP server isn't used to process ECHD requests

*Name of the element isn't displayed in the settings panel of the given object.