Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Control panel object in the video surveillance system with the distributed architecture

NumbersDigits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Control panel objects in the video surveillance system with the distributed architecture

2

The Name*
field

Enter the value in the field

Sets the name of the Control panel object in the video surveillance system with the distributed architecture

Latin alphabet, Cyrillic characters, and service characters

Control panel

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the Control panel object in the video surveillance system with the distributed architecture

Boolean type

Clear

Setthe Control panel object is disabled and isn't used

Clearthe Control panel object is enabled and is used

4

The Telemetry Controller
drop-down list

Select the value from the list

Sets the Telemetry Controller parent object of the system with the distributed architecture to which the given given Control panel object belongs

Name Names of the the Telemetry Controller objects registered in the system

Name of the Telemetry Controller parent object

Depends on the number of telemetry controllers in the video surveillance system with the distributed architecture

The Settings group

5

The Port
drop-down list

Select the value from the list

Sets the number of the computer serial (COM) port used to connect the Control control panel

List of available COM ports 

COM1

Depends on the number of COM ports on the server or Remote Administrator's workstation

6Speed

The Rate
drop-down list

Select the value from the list

Sets the data communication speed via the serial (COM) port

Kb/s


9600

From 300 to 256000

7

The Parity
drop-down list

Select the value from the list

Sets the parity check mode for the data transmission over the serial (COM) port

List Names of the parity check modes

None

Even, Odd, None, Mark, Space

8

The DTR checkbox

Set the checkboxDisables the object

Enables power supply to the control panel via the output of the serial DTR (COM) port

Boolean type

Set

Setthe power is supplied via the DTR port output

Clearthe power isn't supplied via the DTR port output

9

The RTS
checkbox

Set the checkboxDisables the object

Enables power supply to the control panel via the output of the serial RTS (COM) port

Boolean type

Set

Set—the power is supplied via the RTS port output

Clear—the power isn't supplied via via the RTSport output

10

The Priority
drop-down list

Select the value from the list

Sets the priority for controlling the PTZ devices via the Control control panel

Names of priorities used to control the PTZ devices

Low

  • Control prohibited—you cannot control the
  •  PTZ
  • PTZ device using
  • the Control
  • the control panel;
  • Low—you can control the PTZ device after it is controlled by the devices with the standard or high priority;
  • Standard—you can control the PTZ device after it is controlled by the device with the high priority;
  • Highthe PTZ device is controlled first

*Name of the element isn't displayed in the settings panel of the given object.