Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

List of commands and parameters for the SLAVE object is presented in the following table:

Commandcommand description

Parameters

Description

"SETUP"—set parameters for a computer

display_id<>

Display ID

drives<>

Disks for record of video archive

drives_a<>

Disks for record of audio information

flags<>

Flags

arch_days<>

Size of event archive

connection<>

Connection

disable_protocol<>

Disable protocol

ip_address<>

IP-address of device

is_backup<>

Backup

is_load<>

Loaded

local_protocol<>

Local protocol

modem<>

Modem connection

name<>

Object name

password<>

Password

sync_time<>

Time synchronization

username<>

User name

"BACKUP"—backup database

-

-

"CONNECT_ONE"—connect to a computer. Connects the corresponding computer. It is recommended to avoid using of this reaction manually

-

-

"CONNECT_OTHER"—connect to cores. Connects computer to other cores from configuration. It is recommended to avoid using of this reaction manually

-

-

"DISCONNECT_ONE"—disconnect from computer. Disconnects the corresponding computer. Core can be connected automatically in case of disconnection. It is recommended to avoid using of this reaction manually

-

-

"SYNC_PROTOCOL"—run SyncProtocol.exe utility of protocol synchronization. Protocol merging is happened if synchronization is configured

-

-

"SYNC_TIME"—synchronize time. To perform this reaction it is required to create SyncTime parameter with value 1 on the system to which reaction was addressed in the HKEY_LOCAL_MACHINE\SOFTWARE\AxxonSoft\PSIM (HKEY_LOCAL_MACHINE\Software\Wow6432Node\AxxonSoft\PSIM registry section for 64-bits system)

-

-

"CREATE_PROCESS"—run process

command_line<>

Command line. Commands of Windows command line written without hyphens through |, & or && separating characters

"SEND_MY_CONFIG"—send configuration. Send configuration to other computers. The same as “SPREAD_CONFIG”

-

-

"MOVE_CONFIG"—move configuration. Moves configuration created in the objects tree on the basis of the computer–supplier to the computer–recipient

from<>

Supplier

to<>

Recipient

"SPREAD_CONFIG"—spread configuration. The same as “SEND_MY_CONFIG”

-

-

"GET_DEPTH"—get archive depth. The ARCHIVE_DEPTH event (see table below) is formed in response to reaction in system. Absence of one or both parameters concedes request of depth by records for all values of parameter


cam<>

Camera ID for which archive depth is required

drive<>

Disk or network path on which archive depth is required.

Name of disk is specified in the following format: "<letter of disk>:\\", for example drive<D:\\>

Note. The "\" symbol is an escape character.

Network path is specified in the UNC format

"ACTIVATE_DISPLAY"—change the display. The command allows showing the Display with the given identifier on the monitor (monitors) of the computer

display_id<>The identifier of the corresponding Display object. If an empty value is passed to the parameter, then all displays are hidden when running this command

Properties of the SLAVE object are shown in the table.

...