General plugin setup

Some plug-ins have their own settings, the files of which are located in the <POS Intellect installation directory>\Modules\Pos\Forwarders\Protocols\Settings\ folder. Depending on the plugin used (ProtocolName parameter in the mixforward.exe.xml configuration file), you must also configure them. For details, refer to the respective settings files.

Configuring Liko and SecurOS plug-ins

The data receiving from the plug-in is configured in the PluginSettings elements group of the mixforward.exe.xml configuration file.

A description of the elements of the PluginSettings group is given in the table.

Element name

Element description

Element attribute

Attribute description

LikoSettings

Sets the Liko plugin settings if InputPortType = PLUGIN and ProtocolName = Liko

BaseURLAPI base address
LoginAccount login
PasswordAccount password
RequestIntervalEvent information update interval, ms
SecurOSSettings

Sets SecurOS plugin settings if InputPortType = PLUGIN and ProtocolName = SecurOS

Note. If the plugin creates its own detailed log (PrivateLog=true), then the SecurOS plugin log will be located in the <POS Intellect installation directory>\Modules\Pos\Forwarders\MixForward\Protocols\SecurOSLogs\ folder.


BaseApiURLAPI base address
LoginAccount login
PasswordAccount password
CallbackUrlHTTP server address for receiving events from SecurOS
ObjectInfo

Information about the object for which it is necessary to receive events.

Type - object type

id - object id in the system

idTerminal - terminal id to which the information about the POS events will be sent

SubscribeEventRequired event name