The Region object is designed to create zones, which break down secured areas into structural elements. The Region objects allow:

  1. group hardware based on the attributes of a certain region;
  2. execute certain operations concurrently with all objects of the same type belonging to the same region.

The settings panel of the Region object is shown in the figure.

 

The table describes the parameters of the settings corresponding to the elements of the settings panel of the Region object.

Parameter

Method for entering the parameter

Parameter description

Sym-bols used

Default value

Value range

1

Identification number*

Enter the value in the field

Shows the identification number of the Region object in the digital video surveillance system

Sequence of numbers

-

1-65534

2

Name*

Enter the value in the field

Assigns the name to the Region object

Latin, Cyrillic and service characters

Region

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), case-insensitive.

Number of symbols – from 1 to 60

3

Disable

Is identified by the check mark

Shows the status (enabled or disabled) of the Region object in the digital distributed video surveillance system

Boolean type

Not available

Yes – the Region object is disabled and is not in use.

No – the Region object is enabled and is in use

4

Area

Is selected from the list

Assigns the parent Area object, to which the given Region object refers

Name of the Area objects registered in the system

Name of the parent Area object

Depends on the number of Area objects in the digital system

Settings Group

5

Description

Enter the value in the field

Defines the description of the given region

Latin, Cyrillic and service chara-cters

Not defined

A line containing a sequence of any symbols (letters, digits, service characters), case-insensitive.

Number of symbols – from 1 to 60

6

Description

Is selected from the list

Defines the users registered by the system, responsible for the given region

Latin, Cyrillic and service chara-cters

Not defined

Depends on the number of users registered by the system

7

Marker

Select from the list

Specifies the set of signs which will be in use while displaying region on the interactive map

Available set of signs specified by means of the ddi.exe utility

Not specified

Depends on the number of available sets of signs

8

Objects included into region

Automatically

Displays the list of objects related to this region

Type, number and name of objects included into region

Not specified

Depends on the number of the objects related to this region

*The name of the element is not displayed in the settings panel of the given object