The Security zone object is used for the general configuration of Axxon PSIM.

The settings panel of the Security zone object is shown in the figures with tabs. The tables describe the settings.

The Basic settings tab:

 

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1Protocol clear timeEnter the value in the field using the up and down buttonsSets the time of the day at which to start cleaning up the Event Viewer database according to the Events archive length parameterHH:MM:SSCurrent system time at the moment of opening the object settings panelFrom 00:00:00 to 23:59:59

2

Events archive length days

Enter the value in the field

Sets the number of days to store information about the events registered by Axxon PSIM and recorded into both the Event Viewer and the Incident server. This parameter affects all computers in a distributed system

Days

3

From

3

Object code

Enter the value in the field

Sets the number of the access control card, which is automatically displayed in the settings panel of the User object when the object is created in the Object code field

Sequence of numbers

NA

More than 1

4

Starting configuration

Select the value from the list

Sets the macro, which runs automatically when starting Axxon PSIM 

Names of the Macro objects registered in the system

NA

Depends on the number of the Macro objects created in the video surveillance system with distributed architecture

5

Connections in architecture

Set the checkbox

Sets the computers with which the created Computer object must exchange the data about the system configuration parameters: with all computers in the video surveillance system with distributed architecture or only with the Computer object on the basis of which the given object is created

Boolean type

Clear

Setwhen creating a new computer, the Connection checkboxes in the Architecture tab are set for all computers in the architecture

Clearwhen creating a new computer, the Connection checkbox in the Architecture tab is set only for the computer from which this new object is created

6

DNS instead of IP allowed

Set the checkbox

Sets the address of the Server/Remote Administrator’s workstation/Remote Client in the Architecture tab as DNS name, not only IP address

Boolean type

Clear

Set—when configuring the interaction of the computers in the distributed system, you can specify the DNS name (instead of the IP address) of the Server/Remote Administrator’s workstation/Remote Client in the Architecture tab

Clear—when configuring the interaction of the computers in the distributed system, specify the IP address of the Server/Remote Administrator’s workstation/Remote Client in the Architecture tab

7Ping (s)Enter the value in the field

Sets the check period for the computer connection to the server

Note. For servers, this value is saved automatically in the CheckPingPeriod parameter. For the Remote client, you can specify the value manually in the CheckPingPeriod parameter (see Registry keys reference guide)

Sequence of numbers10>=1
8Show documentation by clicking F1Set the checkboxEnables opening documentation in the pdf format by pressing the F1 button when Axxon PSIM is running. The Administrator's Guide section is opened on the Server and the Remote Administrator's workstation; the Operator's Guide section is opened on the Remote ClientBoolean typeClear

Set—the documentation is displayed by pressing the F1 button

Clear—the feature of displaying the documentation by pressing the F1 button is disabled

9Debug statisticsClick the buttonOpens the window with the events queue statisticsNANANA
10Administrator’s passwordClick the buttonOpens the window for specifying the Administrator’s passwordNANANA

11


Internal synchronization: offline

Set the checkbox

Enables the offline synchronization of the events

Boolean type

Set

Set—the offline synchronization is enabled. When the computer is reconnected, it gets all events for the no-connection time period

Clear—the offline synchronization is disabled. When the computer is reconnected, it doesn't get the events for the no-connection time period

Internal synchronization: online

Set the checkbox

Enables the online synchronization of the events

Boolean type

Set

Set—the online synchronization is enabled. The events are sent right after they occur according to the configuration parameters of the computer interaction in the distributed system

Clear—the online synchronization is disabled. The events aren't sent

The Holidays group*

12

Holidays

You can add the dates by clicking the Add button

List of calendar days which are defined as holidays in Axxon PSIM

List of dates.

Date format: DD-MM-YY

NANA

13

Add

Click the button

Opens the Calendar window to select the date of a new holiday

NA

NA

NA

14

Delete

Click the button

Deletes the selected holiday date from the Holidays list

NA

NA

NA

15

Edit

Click the button

Opens the Calendar window to change the date of the selected holiday in the list

NA

NA

NA

16SMS confirmationSelect the value from the listSets the Short Message object for two-factor authentication—see Configuring two-factor authenticationNames of the Short Message objects registered in the systemNADepends on the number of the Short Message objects created in the system

The Date and time format tab

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

17Date formatSelect the value from the list

Sets the format of the date that is displayed in the Incident managerOperator protocol, and Video surveillance monitor in the current date field and when you work with the archive

List of types of date formatCurrent
  • Current—the date format set in the OS;
  • dd/MM/yy—the day/month/year format;
  • MM/dd/yy—the month/day/year format;
  • yyyy-MM-dd—the year/month/day format
18Time formatSelect the value from the listSets the format of the time that is displayed in the Incident managerOperator protocol, and Video surveillance monitor in the current date field and when you work with the archiveList of types of time formatCurrent
  • Current—the time format set in the OS;
  • HH:mm:ss24-hour format;
  • hh:mm:ss tt12-hour format

The RabbitMQ tab

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

19ServerEnter the value in the fieldSets the RabbitMQ server addressLatin characters, numbers, and service characterslocalhostServer IP address or name
20PortEnter the value in the fieldSets the RabbitMQ host portNon-negative integersNot defined

From 0 to 65535

If the port is 0 or not specified, RabbitMQ won't run

21UserEnter the value in the fieldSets the RabbitMQ host usernameLatin characters, numbers, and service charactersguestDepends on the registered RabbitMQ users
22PasswordEnter the value in the fieldSets the RabbitMQ host user passwordLatin characters, numbers, and service charactersguestDepends on the registered RabbitMQ users
23Content-typeSelect the value from the listSets the type of the sent/received contentSupported types of contentplain/text
  • application/json—a message in JSON format is sent;
  • plain/textThe Axxon PSIM event is sent in the "TYPE|ID|EVENT" format.

*Name of the element isn't displayed in the settings panel of the given object.