Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 9 Next »

The settings panel of the SIP-terminal system object is shown in the figures below.

The table describes the setting parameters of the SIP-terminal system object.

Parameter

Method for setting the parameter value

Description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the SIP-terminal system object

Numbers, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the SIP-terminal objects in the system

2

Name*

Enter the value in the field

Sets the name of the SIP-terminal object in the system

Latin, Cyrillic, and service characters

SIP-terminal

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Disables the SIP-terminal object in the system

Boolean type

Clear

Setthe SIP-terminal object is disabled and isn't used

Clearthe SIP-terminal object is enabled and used

4

Computer

Select the value from the list

Sets the Computer parent object for the given SIP-terminal object

Name of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the system

5Terminal typeSet the switch in the required positionSets the SIP-terminal typeSupported SIP-terminal typesSIP server

SIP server—the SIP-terminal acts as a server, any SIP-clients can be connected to it

SIP client—the SIP-terminal acts as a client, it can be connected to any SIP server

*Name of the element isn't displayed in the settings panel of the given object.

The Basic settings tab

The table describes the setting parameters of the Basic settings tab.

Parameter

Method for setting the parameter value

Description

Representation

Default value

Value range

1NetworkSelect the value from the list

Sets the IP address of the network adapter that is used to connect to the network in which the SIP-clients are located

IP addressDefault network adapterThe list of the available network adapters of the computer
2SIP portEnter the value in the field

Sets the port number which will receive the data from the clients via the SIP protocol

Integer numbers5060From 0 to 65535
3SIP transportSelect the value from the list

Sets the used transport layer protocol

Supported transport layer protocolsUDP

TCP

UDP

4RTP ports range, from and to fieldsEnter the value in the field

Sets the RTP ports range

Integer numbers

from 40000 to 64000

From 0 to 65535
5AddressEnter the value in the field

For the SIP client terminal type only.

Sets the IP address of the SIP server

IP addressNA1.0.0.0255.255.255.255
PortEnter the value in the field

For the SIP client terminal type only.

Sets the port for the SIP server connection

Integer numbersNAFrom 0 to 65535

The Advanced settings tab

The table describes the setting parameters of the Advanced settings tab.

Parameter

Method for setting the parameter value

Description

Representation

Default value

Value range

1Subscriber Enter the value in the fieldSets the SIP server special numberInteger numbersNA>=0
2NameEnter the value in the fieldSets the name of the SIP server special numberLatin, Cyrillic, numbers, and service charactersNAA line containing a sequence of any characters

The Numbers settings tab

The table describes the setting parameters of the Numbers settings tab.

Parameter

Method for setting the parameter value

Description

Representation

Default value

Value range

1SubscriberAutomaticallyDisplays the numbers of all devices and operators registered on the SIP-terminal, as well as special numbersNANADepends on the number of devices and operators registered on the SIP-terminal, as well as special numbers
2NameAutomaticallyDisplays the names of the corresponding devices, operators, and special numbersLatin, Cyrillic, numbers, and service charactersNAA line containing a sequence of any characters
3RedirectingEnter the value in the fieldSets the number or numbers to which the corresponding subscriber's calls must be forwardedSequence of numbersNANumbers of all devices and operators registered on the SIP-terminal, as well as special numbers. If you want to specify several numbers, use a semicolon as a separator, for example, 234;12;0983
4Pending, sEnter the value in the fieldSets the time period in seconds during which it is necessary to wait for a response from the subscriberSequence of numbersNA>0
5One responderSet the checkboxEnables the reset of a group call forwarded to several numbers after one of the recipients answersBoolean typeClear

Set—a group call is reset for all recipients after the response of any operator or a device

Clear—the group call isn't reset after the answer of the first or subsequent operators and/or devices, that is, all recipients can join the call

6Run macroSelect the value from the listSets the Macro object, which must be run when calling to subscribe

Name of the Macro objects registered in the system

NADepends on the number of the Macro objects in the system
7Calling number multicast (video)Enter the value in the fieldSets the IP address for transmitting the video stream from the calling device in the Multicast modeIP addressNA1.0.0.0255.255.255.255
8Calling number multicast (audio)Enter the value in the fieldSets the IP address for transmitting the audio stream from the calling device in the Multicast modeIP addressNA1.0.0.0255.255.255.255
9Destination number multicast (video)Enter the value in the fieldSets the IP address for transmitting the video stream from the destination device in the Multicast modeIP addressNA1.0.0.0255.255.255.255
10Destination number multicast (audio)Enter the value in the fieldSets the IP address for transmitting the audio stream from the destination device in the Multicast mode drop-down listIP addressNA1.0.0.0255.255.255.255
  • No labels