To configure VMD, you must perform the following steps:

  1. In the Detection Tools list, highlight a Motion object (1).

  1. In the Sensitivity field: contrast (2) , enter the sensitivity of the detection tool to object contrast. You should select a value empirically in the range [0, 16]. The greater the value, the less contrastive the objects which can be detected.
  2. In the Sensitivity field: size (2), enter the sensitivity of the detection tool to object size. You should select a value empirically in the range [0, 10]. The greater the value, the smaller the objects which can be detected.
  3. In the viewing tile, set detection zones and/or masks in the same way as for situation analysis detection tools (3).

Note: See steps 2–4 in the section Setting Common Detection Zones and Masks.

  1. Click the Apply button.

VMD configuration is now complete.