Documentation for Auto Intellect 5.0. Documentation for other versions of Intellect is [available too].

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Events search is set up in the following way:

  1. Select the database, where events should be searched.
  2. Set up the displaying of events search.
  3. Set up the video archive.
Selecting recognizer databases for events search

To select recognizer databases for events search, select servers where required LPR databases are. To carry this out select the point «Servers» -> «<Name of the required database>» of the main menu in the «Event search in the Recognizers DBs » window (Fig. 4.3—47). As a result the server will be marked with «» icon.

Fig. 4.3—47 Selecting recognizer database for event search
Note. To select all system servers select the point «Servers» -> «Select all».
There will be search by selected servers.

Event search results setup

Event search results are presented in the table. There is a possibility to choose which table's columns should be displayed and which shouldn't, to add new columns and also edit their displayed names.
To set up the displaying of search results do the following:

  1. Select «Settings» in the main menu of the Events search in recognizers databases (Fig. 4.3—48).



Fig. 4.3—48 Access to search results setup
As a result Settings dialog box is displayed. (Fig. 4.3—49). Set up of the event search results displaying is carried out in «Configure fields» tab.

Fig. 4.3—49 Settings window

  1. In the central field of the window (Fig. 4.3—49, 1) set the checkboxes for the columns that should be displayed in event search results table (Table 4.3—2).

Note. For displaying all the available columns in the search results table set the checkbox «Select/deselect» (Fig. 4.3—49, 2). If this checkbox isn't set, search results table is not displayed.
Table 4.3—2 Event search results table's columns

Column name (on default)

Column's content

Frame

Video frame with a vehicle

Vehicle's speed

Vehicle's speed

Number

Identified plate's number

Region number

Region of identified number

Country

Country of the identified number

Detector name

Object name «LPR channel», corresponding to Vehicle's detector number

Date

Data of vehicle's identification

Detector address

Number's detector address

Valid speed, km\h

Speed in km\h , that is valid on the road's area/ controlled by number's detector

Overspeed, km\h

Vehicle's overspeeding in km\h

Direction

A check, that the vehicle was moving towards the camera, detecting numbers

Authenticity, %

Plates identification authenticity is given in percent

Alarm time

Time of alarm registration according to the identified number

Alarm detection time

Time of alarm detection by the PC operator of the Auto-Intellect

Delay of alarm acceptance, sec

Time between registering the alarm and its acceptance by operator

Commentary

Commentary , added by the operator to the event with a vehicle

Alarm type

Alarm type(overspeeding or vehicle's identification in the external plates databases)

Alarm processed

A check, that the alarm has been accepted by the operator

External database

A check, that the alarm has been found in the External database

Alarm initiated by

Operator name who initiate the alarm

Alarm accepted by

Operator name who process the alarm

Red-light phase start time

Time of start alarm during which alarm was fixed

Time passed since the red-light phase start

Time period passed since the red-light phase starts until the alarm fixing moment

  1. To add a new column to the event search results table do the following:
    1. Click Add (Fig. 4.3—49, 3). As the result Fields configuration dialog box opens (Fig. 4.3—50).


Fig. 4.3—50 Adding a new column to the event search results table

    1. In the «Field name in the DB» enter the column's name in the connected recognizer's database, which content is required to be displayed in the event search results table ( Fig. 4.3—50, 1).
    2. In the «Field name in the interface» enter the name of this column in the event search results table (Fig. 4.3—50, 2).
    3. Click «Save» to save the applied changes and close «Fields configuration» dialog window (Fig. 4.3—50, 3).

Note. Click «Cancel» to close this window without saving any changes (Fig. 4.3—50, 4).

  1. To edit column's name in the event search results table do the following:
    1. In the group «Available fields» select the column, the name of which has to be changed (Fig. 4.3—49, 1).
    2. Click «Edit» (Fig. 4.3—49, 4).
    3. As a result «Configure fields» dialog box with blocked «Field name in the interface» field is displayed (Fig. 4.3—51).


Fig. 4.3—51 Editing the column's name in the event search results table

    1. Change the columns name in a required way in the event search results table and save the changes (see steps 4.3-4.4).
  1. Click «OK» to save the changes and close the «Displayed fields selection» dialog window (Fig. 4.3—49, 5).

Note. Click «Cancel» to close this window without saving any changes (Fig. 4.3—49, 6).
Setting up the event search results is completed.

Set up the video archive

Video recordings of events are displayed in video archive. To set up the video recordings playback do the following:

  1. Select «Settings» in the main menu of the Event search in Recognizers DBs (Fig. 4.3—52)


Fig. 4.3—52 Access to search results setup
As a result «Settings» dialog box is displayed (Fig. 4.3—53).
Fig. 4.3—53 Settings dialog box

  1. Go to «Configure video archive » tab (Fig. 4.3—54, 1)


Fig. 4.3—54 Video archive setting

  1. Select Overlay mode in the Overlay dropdown list.( see Table 4.3—3, Fig. 4.3—54, 2)

Note. Overlay is used to process the video using the video card and Direct X libraries, before it is displayed. Overlay allows to improve the image due to optimization of the pixel color settings. At the same time, the CPU's load reduces as the video is processed with the resources from the video capture card.
Table 4.3—3 Overlay mode

Overlay mode

Description

«No»

Videos from video cameras are not processed by video card

«Overlay 1»

Videos from video cameras are processed as one stream

«Overlay 2» (set on default)

Videos from video cameras are processed independently of one another


  1. In «Compression» field set the cursor in position that determines video compression degree (see Fig. 4.3—54, 3). Minimal compression value is «None» – maximal video size, best quality. Maximal compression value is «Maximum» – minimal video size, worst quality.
  2. To save changes click «ОК» (see Fig. 4.3—54, 4).

The setting of the events video recordings playback is completed.