Documentation for Intellect 4.10.4. Documentation for other versions of Intellect is available too.

Previous page Next page


INTELLECT™ provides the PTZ control option using the Operator query panel interface object. The Operator query panel interface object is an individual user dialog box with the relevant elements to control a certain type of PTZ device.

The unique control panel is designed by the PTZ device vendor and is bundled with the PTZ software. The files of the unique PTZ control panels are stored in the Program folder of the INTELLECT™ installation directory.

Create and configure the Operator query panel as follows: 

  1. Open the Programming tab in the System settings dialog box (1).
  2. Create a Macro object under the Macros object in the Programming tab (2). Specify the object's ID and name.

    Note

    The Macro object is necessary to refer to INTELLECT™ core and to display the Operator query panel on the screen.


  3. Open the Hardware tab in the System settings dialog box (3).
  4. Create the Operator query panel object under the Computer object in the Hardware tab (4).
  5. Specify the file name (without extension) of the dialog box, used for PTZ device control, in the ID field (5). The necessary files are stored in the program folder of the INTELLECT™ installation directory.
  6. To activate the moving option for the Operator query panel object, set the Allow moving checkbox checked (6).
  7. Specify the X and Y coordinates of the Operator query panel position on the screen in the relevant fields. The X and Y settings correspond to the screen coordinates of the top left corner of the Operator query panel and are shown as percentage of the horizontal and vertical screen sizes correspondingly (7).
  8. Select the type of the Macro objects in the list of objects and events (8).
  9. Specify the ID of the Macro object, created to call up the Operator query panel (9).
  10. The name of selected Macro object is automatically displayed in the Name column (10).
  11. Select the Action executed item in the list of possible events (11).
  12. To save the changes click the Apply button (12).