To configure the AR-727 controller, do the following:

  1. Go to the AR-727 object's settings panel.
  2. From the Region In drop-down list select the Area located in the site of exit through this reader (1).
  3. From the Region Out drop-down list select the Area located in the site of entry through this reader (2).
  4. From the Mode drop-down list select the required mode of the controller (3). Available modes are presented in the table.

    Mode

    Networking/ Stand-Alone

    User   Capacity

    Access Mode

    Auto-show Duty time

    Event log Capacity

    120 Holidays

    Anti force

    Time Zone

    Lift Control

    Anti-pass-back

    M4

    Networking/ Stand-Alone

    1,024/3,000 (725H)

    1.Card only.

    2.Card and PIN (4-digit PIN)+#.

    3.Card or User address (5-digit) + Individual PIN (4-digit individual PIN)+#.

    Yes

    1200/1500 (725H)/3000 (757H)

    Yes

    Yes

    11

    32

    Yes

    M6

    Stand-Alone

    65,535

    1. Card only.
    2. Card and PIN (4-digit public PIN=Arming PWD)+#.
    3. Card or PIN (4-digit public PIN=Duress code).

    No

    No

    No

    No

    No

    No

    No

    M8

    Networking/ Stand-Alone

    1,024/3,000 (725H)

    1.Card only.

    2.Card and PIN (4-digit individual PIN)+#.

    3.Card or PIN (4-digit individual PIN).

    Yes

    1200/1500 (725H)/3000 (757H)

    Yes

    Yes

    11

    32

    Yes

    Attention!

    The connection between the AR-727 controller and the ACFA Intellect software will not be established while the M6 mode selected.


  5. Click Set up Time Zones to configure the matching between time zones of device and time zones of Intellect Server (4) .

    1. In the Intellect TZ column select the time zone in ACFA Intellect corresponding to the time zone of Soyal device (1).
    2. Click OK to confirm changes (2).
  6. In the Duress password field enter the code which is using when the computer opens door and at the same time sends a message for help (5).
  7. In the Master password field enter the code which allows programming device (6).
  8. In the Arming password field enter the code for arming (7).
  9. In the Base configuration section enter the time of relay activation and delay time (8).
  10. In the Extended option sections select the needed function settings checkboxes (9). Descriptions of all options see in the vendor documentation.
  11. Click the Apply button.

Configuring parameters of the AR-727 controller is completed.