Go to documentation repository
Previous page Next page
The AIO relay is configured on the settings panel of the Apollo AIO Relay object created on the basis of the Apollo AIO object.
The AIO relay is configured as follows:
- From the Number: drop-down list select the number of relay (1).
From the Mode: drop-down list select the mode of relay working (2).
Mode of relay working Description Disabled Relay opened Enabled Relay closed Connected with inputs locally State of relay depends on state of loops and inputs - From the Mask by time zone: drop-down list select the time zone during which events won't be generated for the relay (3).
- Specify duration of relay impulse:
- From the Measurement unit: drop-down list select the measurement unit of relay impulse (5).
- In the Duration of impulse field set the value in selected units defining the impulse duration (4).
- Set the Bind with "binding" input checkbox if it's required that relay reacts to the Binding state of input (6).
- Set the Bind with failure at any input checkbox if it's required that relay reacts to failure of any input (7).
Overview
Content Tools