Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


Attention!

Integration with ECHD requires Intellect user credentials that do not contain special characters (such as \, /, :, *, ?, |, ", etc.) in the login and password—it is a specific feature of configuring the stream transmission via RTSP.

Integration with Single Data Center (ECHD) is supported in Intellect. Requests to Intellect are made in ECHD using HTTP API—see Intellect HTTP API. Some requests have http/https interface. These requests are used to get info on configuration. The RTSP Server bound to the Web-server object streams live or archived video.

Besides binding the Web server to the RTSP server, the ECHD channel objects are to be created under the Camera object for ECHD requests operation.

Note.

Information on how to create and configure the RTSP Server object is given in Configuring RTSP Server module section.

Bind RTSP Server object to process ECHD requests as follows:

  1. Go to the Basic settings tab on the settings panel of the Web-server object (1).
  2. Set the ECHD translation checkbox (2).
  3. Select created and pre-configured RTSP Server object in the RTSP Server drop-down list (3).
  4. If the CCTV servers are located behind NAT when interacting with the ECHD, then to use the NAT address (4), set the Use NAT address checkbox to substitute the router address in the ECHD requests.

    Note

    The address and port of the router are set during the configuration of the RTSP Server object.

  5. Click the Apply button (5).

The RTSP Server object is now bound to Web-server object.