Previous page Configuring the MorphoAccess SIGMA Lite controller in GPIO mode  Configuring the MorphoAccess SIGMA Lite regions Next page


The MorphoAccess SIGMA Lite controller operation in the SDAC mode (single door access control) is configured as follows:

  1. In the Door Unlock Duration field (1) enter the time in seconds during which the door will be unlocked.
  2. In the Door Held Open Duration field (2) enter the time in seconds, during which the door should be closed. Otherwise, the Hold Door event will be generated.
  3. From the Request to Exit Mode drop-down list (3) select the exit mode:
    1. None - not specified.
    2. Push Button - exit by the button pushing.
    3. <Reserved> - reserved mode.
  4. From the Type Door drop-down list (4) select the door open mode:
    1. Manual Door Open - the door is opened manually.
    2. Electric Door Open - the door is opened automatically.
  5. In the Egress Timeout field (5) enter the time in seconds, during which the door will remain opened if the Push Button exit mode and Manual Door Open door open mode are selected. 

    Note.

    The value in the Egress Timeout field should be within the range from 1 to 300 seconds.
  6. Set the Enable Time Override Mode checkbox (6), if it is necessary to enable the time override mode. This mode allows to open the door to a previously authorized user without any authentication within the time specified in the Time override Mode Timeout field (7).
  7. In the Time override Mode Timeout field (7) enter the time in seconds, during which a previously authorized can open the door without any authentication.
  8. Click Apply (8) to apply the changes.

Configuring the MorphoAccess SIGMA Lite controller in the SDAC mode is complete.

  • No labels