You can configure common settings of a Hikvision reader via the Hikvision 26X Reader, Hikvision 28X Reader, and Hikvision K1T605XF Reader objects configuration panel, which are created on the basis of the Hikvision 26X, Hikvision 28X, and Hikvision K1T605XF objects manually or automatically after reading the configuration from the corresponding controller (see Network settings of the Hikvision controller and Configuring the Hikvision controller). As an example of configuring the common settings of a Hikvision reader, let's consider a Hikvision 26X controller.
To configure the Hikvision reader common settings, do the following:
- Go to the Hikvision 28X Reader object setup panel.
- From the Direction drop-down list (1), select the reader's direction: Exit or Entrance.
- Go to the Common tab (2).
- The Description field (3) displays a brief description of the reader.
- The reader type is displayed in the Reader type name field (4).
- Check the Enable reader box (5) to activate the reader.
- From the OK LED polarity drop-down list (6), select the buzzer's polarity on a successful card swipe.
- From the Error LED polarity drop-down list (7), select the buzzer's polarity on a successful card swipe.
- From the Buzzer polarity drop-down list (8), select a reader buzzer's polarity.
- In the Min. card swiping interval, s field (9), specify the minimum time interval between two consecutive card swipes. You can set the interval from 0 to 255 seconds.
- In the Max. interval for password digit, s field (10), specify the timeout interval between consecutive pressings of numeric keys while entering the password. If the time interval exceeds the timeout value, all previous entries are cancelled.
- Check the Failed attempts limit box (11) to automatically generate an alarm in case of exceeding the permitted number of card swipes set in the Max. times of card swiping failure field (12).
- In the Max. times of card swiping failure field (12), set the critical number of consecutive card swipes to generate an alarm if the Failed attempts limit box (11) is checked.
- Check the Tampering detection box (13) to enable the detection of device tampering attempts.
- In the Detect when reader is offline for, s field (14) field, specify the timeout interval to de-activate the reader on lost connection to the Hikvision controller.
- From the Entrance drop-down list (15), select the section located on the door entry side.
- From the Exit drop-down list (16), select the section located on the exit side of the door.
- Click Apply button (17).
The Hikvision reader common settings are now configured.