Go to documentation repository
Previous page Next page
The Suprema 2 controller is configured as follows:
- Go to the Suprema 2 Host object settings panel. The object is created based on the Suprema BiometricalACS v2 object.
- In the Address (1) field, set the IP-address of the Suprema 2 controller.
- In the Port (2) field, set the port of the Suprema 2 controller.
- In the ID (3) field, specify the identification number of the controller connected via Ethernet.
- From the Region in (8) drop-down list, select the Region corresponding to the area located at side of exit through the reader.
From the Region out (9) drop-down list, select the Region corresponding to the area located at side of entrance through the reader.
Note.
The Region in and Region out are to be selected if Time&Attendance interface module is in use. Otherwise, leave these fields empty.
- Click Write Users (6) to send users to the controller.
- Click Set Time (7) to synchronize controller time with Server time.
- Enable controller options:
- Set the Support Pin (8) check box if the controller supports authorization by password.
- Set the Support Card (9) check box if the controller supports authorization by card.
Set the Support Fingerprint (10) check box if the controller supports authorization by fingerprint.
- Set the Support Face (11) check box if the controller supports authorization by face.
Note.
Only set the check boxes for options supported by the Suprema 2 controller.
- Click Read Options (12) to read supported options from the controller.
- Click Synchronize devices tree (13) to automatically create objects in ACFA Intellect hardware tree according to the devices connected to the controller.
- Click Apply to save changes (14).
Configuring the Suprema 2 controller is completed.