Configuration of the logical condition for terms processing is carried out in the following order:
- Go to the Apollo Internal Variable object settings panel.
Set the Term handling type. Execute when modified switch to one of the positions described in the table below (1).
Switch position
Description
any term, result – logical OR of all terms
Actions specified in the internal variable will be executed when any term is changed, provided that the logical OR of all terms is TRUE.
logical OR of all terms, result – logical OR of all terms
Actions specified in the internal variable are performed if at least one term is TRUE.
logical AND of all terms, result – logical AND of all terms
Actions specified in the internal variable are performed if all terms are TRUE.
any term, result – modified term value
The actions specified in the internal variable will be performed when any term is changed.
- Click Apply (2).
- To save the changes to the controller, write configuration to hardware.