Go to documentation repository
Previous page Next page
Setting up the TREZOR-M receiver is performed in the following way:
- Go to the Trezor M receiver (Trezor) object settings created on the base of the Bus RS-485 (Trezor).
For the Address parameter (1), specify the address of the connected receiver (from 0 to 255).
Note
The Address with a ‘0’ value (or ‘00000000’ in binary code) is meant for executing utility functions.
The receiver address is set up with the eight-bit switch on the receiver circuit plate.
- For the crossSpeed parameter (2), specify the speed at which the trespasser intersects the detection zone.
- For the frequencyChannel parameter (3), specify the frequency character of the receiver.
- For the Threshold parameter (4), specify the receiver threshold.
- Click Apply (5).
The TREZOR-M receiver is configured.
Overview
Content Tools