Documentation for Axxon One 1.0.

Previous page Adding and removing IP devices  Configuring system objects for devices Next page

You can add IP devices in bulk by importing their parameters from a CSV file.

Attention!

You have to disable the UAC first.

Do the following:

  1. Create a CSV file with devices listed as follows:

    IP address, Port, Vendor, Model, Login, Password, Identifier, Object name, Latitude, Longitude, Azimuth, Archive name, Recording mode

    Attention!

    For each added camera, three parameters are required: IP address, Vendor and Model.

    If a required parameter is not specified, it will be automatically set to its default value. 

    You should include commas even if no additional parameters are set.

    Note

    To separate the integer and fractional parts in coordinates, use a point.

    For example:

    10.0.12.245, 80, Bosch, Dinion IP starlight 8000 MP, service, Admin12345!, 1441, Camera 1, 0, 0, 0, Archive AliceBlue, Always
    10.0.12.246,, Bosch, Dinion IP starlight 8000 MP,,,,,,,,,
    10.0.12.247, 80, Bosch, Dinion IP starlight 8000 MP,,,, Camera 3,,, Archive AliceBlue, On motion

    Attention!

    The vendor and model of the device must be specified exactly as in the list of supported devices.

    Note

    For correct display of the object name in Axxon One VMS, the CSV file must be UTF-8 or UTF-32 encoded.

  2. Drag & drop the created file to the field in IP Device Discovery Wizard in Axxon One.

The devices will be added to the configuration.

  • No labels