Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


To configure the filter of events that the Web server 2.0 module must send to the Client, do the following:

  1. Go to the Events subscription tab on the settings panel of Web server 2.0 object.
  2. In the User permissions list, select the User permissions object for which you want to configure the event filter (1). Events that match the filter will be sent only to clients on which users with the selected permissions are connected. Different filters can be configured for different user permissions.

    Note

    The User permissions objects are created and configured on the Users tab of the System settings dialog window (see Rights administration).

    Attention!

    Only users added to the selected permissions have access to the Web server 2.0.

  3. From the Object type drop-down list, select the type of object from which you want to send events (2).

    Note

    The Object type list contains only the object types that are included in the user's current permissions. If user permissions have not been selected, the list of object types is empty.

  4. From the Name drop-down list, select the name of the object of the specified type from which the events are to be sent, if it is needed (3).
  5. From the Event drop-down list, select the type of the event coming from objects of the specified type which is to be sent (4).
  6. If necessary, in the Add. info field, enter additional information about the event that must be sent, which is displayed in the client (5).
  7. If you want to authorize sending push notifications about events of the selected type to the mobile client, set the Push-messages checkbox (6). For push notifications to function, it is necessary for the mobile client to have connected to the Server at least once. This enables the Server to get user account information and the ID of the device to which push notifications must be sent. The device must also have an active Internet connection.

    Note

    • If sending push notifications is disabled and the client is not connected to the Server, then when a message of the selected type appears, it will not be sent.
    • For push notifications to work in Axxon PSIM, the server must be registered in the AxxonNet cloud service (for details, see Cloud authorization for sending Axxon PSIM push notifications).
    • Sending notifications about events of the selected type is also possible using the WebSocket communication protocol. To do this, add the ActiveWebSocke registry key, see Registry keys reference guide.
  8. Go to the next row of the table (arrow "down" on the keyboard) and repeat steps 3-6 for all required events.
  9. Repeat steps 2-7 for all required user permissions.

  10. Click the Apply button to save settings in Axxon PSIM (7).

Configuration of the event filter for the Web server 2.0 module is completed.

  • No labels