Documentation for ACFA PSIM

Previous page Next page


To configure the Sigur ACS access points, do the following:

  1. Go to the settings panel of the Sigur access point object, which is created on the basis of the Sigur server object in the Hardware tab of the System settings window.
  2. In the ID field (1), enter the access point number on the Sigur server.

    Note

    The Configuration field (2) displays the access point configuration, which is set using the switch on the card of the corresponding Sigur ACS controller.

  3. From the Access point type drop-down list (3), select the type of access point managed by the controller:
    • Barrier;
    • Door;
    • Gate;
    • NFC terminal;
    • Turnstile.
  4. From the Entrance drop-down list (4), select the Region object corresponding to the area on the side of the exit from the access point.
  5. From the Exit drop-down list (5), select the Region object corresponding to the area on the side of the entrance to the access point.
  6. Set the access control parameters at entrance and exit (6):
    1. From the Entrance and Exit drop-down lists, select the decision-making side for granting access:

      1. Software decidesaccess decision is automatically made by ACFA PSIM.
      2. Operator decidesaccess decision is made by the operator.

        Note

        To process the request by the operator, you must create the Event manager interface object. Set the display rule to the Request to operator for entrance and Request to operator for exit events and create two operator reactions: Allow access (operator) and Forbid access (operator), as well as create two buttons corresponding to these reactions in the template of displaying. For more information about this object and its functions, refer to Guide for configuring and working with the Event Manager integration module.
    2. Set the Don’t wait access cycle for entry and Don’t wait access cycle for exit checkboxes if you want to record the access immediately after placing the access card to the reader. In case the access is considered to be performed only after passing the access point (that is, the door sensor generates an event), clear this checkbox.
  7. Click the Apply button to save the changes (7).