The AIM interface module is configured on the settings panel of the Apollo AIM object created on the basis of the Apollo AAN Port object.

To configure the AIM interface module, do the following:

  1. Select the type of the AIM module from the corresponding list (1).
  2. From the Address: drop-down list select address of module in internal network (2).
  3. Set the corresponding checkboxes if bounded readers are in use (3).
    Bounded readers are used from both sides of door. Single readers are used from one side of door, access from another side is performed by button.

    Note.

    The SDK ID (4) field is filled in automatically while object creating and it contains different values for objects of the same type. It's not recommended to create objects by template (see The Save function) for correct working of module because of equal SDK ID values.

  4. Click the Apply button.

The AIM interface module is now configured.